3. Click SAVE in Vera and wait till new settings are saved in Vera.
Your Temperature Sensor is set up.
You may want to change its name or assign it to room.
Con
fi
guring the Illumination Sensor
NOTE:
There are no con
fi
gurable parameters related to the
Illumination Sensor.
You have to change the UPnP
fi
les to enable proper integration and presentation of
the Illumination Sensor in Vera. The preinstalled UPnP device for your Illumination
Sensor is “LightSensor”.
1. Open settings box for “
_GenericIO
” with
altid=e2
in Vera dashboard. Go to “Device Op-
tions” tab.
2. Replace the content of the following two
fi
elds with the values provided below:
3. Click SAVE in Vera and wait till new settings are saved in Vera.
4. Press the temper button on the device and keep it for 3-7 seconds, then release. This is to
wake up and propagate the settings.
device_type = urn:schemas-micasaverde-com:device:LightSensor:1
device_
fi
le = D_LightSensor1.xml
Your Illumination Sensor is set up.
You may want to change its name or assign it to room.
By now, all your three sensor should be set up in Vera and you should see the following
three logical devices in the Vera dashboard (See below picture).
If you still see old “_GenericIO” devices (so in total more then three) that means Vera
didn’t refreshed your dashboard yet. Try to refresh it manually by clicking on the refresh
button (see below in red)
You can test or re-con
fi
gure the sensor, by setting up scenes with motion sensor as an
event and by changing the timeout settings as per above steps.
8