3. Click SAVE in Vera and wait till new settings are saved in Vera.

Your Temperature Sensor is set up. 

You may want to change its name or assign it to room.

Con

fi

 guring the Illumination  Sensor

NOTE: 

There are no con

fi

 gurable parameters related to the 

Illumination Sensor.

You have to change the UPnP 

fi

 les to enable proper integration and presentation of 

the Illumination Sensor in Vera. The preinstalled UPnP device for your Illumination 

Sensor is “LightSensor”.

1. Open settings box for “

_GenericIO

” with 

altid=e2

 in Vera dashboard. Go to “Device Op-

tions” tab.

2. Replace the content of the following two 

fi

 elds with the values provided below:

3. Click SAVE in Vera and wait till new settings are saved in Vera.

4. Press the temper button on the device and keep it for 3-7 seconds, then release. This is to 

wake up and propagate the settings.

device_type = urn:schemas-micasaverde-com:device:LightSensor:1

device_

fi

 le = D_LightSensor1.xml

Your Illumination Sensor is set up.

You may want to change its name or assign it to room.

By now, all your three sensor should be set up in Vera  and you should see the following 

three logical devices in the Vera dashboard (See below picture).

If you still see old “_GenericIO” devices (so in total more then three) that means Vera 

didn’t refreshed your dashboard yet. Try to refresh it manually by clicking on the refresh 

button (see below in red)

You can test or re-con

fi

 gure the sensor, by setting up scenes with motion sensor as an 

event and by changing the timeout settings as per above steps.

8

Содержание DHS-ZW-SNMT-01

Страница 1: ...Z Wave Motion Sensor User Guide DHS ZW SNMT 01 Works with VERA 2 3 Lite LAGOTEK...

Страница 2: ...Using Motion sensor in Vera Scenes 9 Creating motion detected events in Vera scenes 9 Using Temperature Sensor in Vera Scenes 9 Creating conditions in Vera scenes based on temperature readings 10 Usin...

Страница 3: ...sor can only communicate to devices within the same Z wave home network Always follow your controller s specific instructions for Z wave inclusion exclusion association or temperature reading Inclusio...

Страница 4: ...cator light blinks 3 times rapidly 7 Mounting successful indicator light is on for 1 second Integration with Vera Home Controller MiCasaVerde Vera2 3 Lite refered later as Vera some minor differences...

Страница 5: ...ed NWI mode is applicable for other Z Wave controllers and for simplicity this method is not presented here 4 Please press the tamper switch at the back of the device for 3 8 seconds 5 After 3 5 secon...

Страница 6: ...ive 1 Open settings box for _Motion Sensor in Vera dashboard Go to Device Options tab 2 Click on Add configuration settings Fill out the fields a Variable type 2 b Data Size choose 2 byte hex c Desire...

Страница 7: ...Size choose 2 byte hex c Desired Value type required Temperature Offset value e g 5 3 Click SAVE in Vera and wait till new settings are saved in Vera 4 Press the temper button on the device and keep i...

Страница 8: ...and wait till new settings are saved in Vera 4 Press the temper button on the device and keep it for 3 7 seconds then release This is to wake up and propagate the settings device_type urn schemas mica...

Страница 9: ...s tab Add Event Vera or New Scene Triggers Vera 3 Lite UI5 Device Motion sensor Type of Event A sensor door windiow motion etc is tripped Name whatever Tripped Yes 4 Create second scene in Vera in sta...

Страница 10: ...e tool It is strongly recommended to read instructions on luup and luup codes in Vera scenes on http wiki micasaverde com for more details Creating conditions in Vera scenes based on illumination read...

Страница 11: ...e sensor and try to include it again Q Why doesn t the Z Wave sensor detect any movement A 1 The Z Wave sensor isn t included in a Z Wave network Include it and try it again 2 The batteries are almost...

Страница 12: ...sleep mode the device is not active listening the device will wake up according to the wakeup command class Include Initiator The include initiator is used when Primary and Inclusion Controllers inclu...

Страница 13: ...off time is done a basic off message is sent to the associated node Default value 0x0A8C 2700 sec 45 min Size 2 bytes integer Param1 the most significant byte of the integer Param2 the least significa...

Страница 14: ...device will send an unsolicited report to the controller if the status is changed the value 0x00 will indicate that the tamper is placed correctly on the wall The value 0xFF will indicate a tamper ala...

Отзывы: