NOTE:
The Z-Wave Motion Sensor must be included into your Z-Wave home network
before it can send and receive Z-Wave commands. Z-Wave Motion Sensor can only
communicate to devices within the same Z-wave home network.
Before including the product to your Z-wave network it is advised to perform Exclu-
sion procedure to reset network settings.
Exclusion (un-pairing) of the sensor from Z-Wave home network
1.Remove (if there were any) batteries from the sensor, and install them again.
2.
Press and hold
a Z-Wave button on the back side of a Vera for
3 seconds
. After releasing the
Z-Wave button a Z-Wave led on front panel of the Vera should
blink quickly
. That means that
Vera is in Z-Wave
exclusion mode
.
3. Please press the tamper switch at the back of the device for
3-8 seconds
.
4. After
3-5 seconds
, the led will blink
three times
; you can now release the button.
5. Exclusion should start immediately.
Very quick blinking
on the Z-Wave led on Vera front
panel, followed by
one second
long, solid light of the sensor’s led indicates successful exclu-
sion.
6. Press and release
twice
a Z-Wave button on the back side of a Vera.
7. Wait till Vera
fi
nish recon
fi
guration of the Z-Wave interface. Progress is presented in the
top, right hand side corner of the Vera dashboard.
8. Repeat the above steps if you haven’t observed indication of a successful
Exclusion
, as per
step 5 above.
Including the sensor into Vera Z-Wave Home Network
NOTE:
The method described is a Classic mode inclusion. The other, more advanced meth-
od, called NWI mode, is applicable for other Z-Wave controllers and for simplicity this
method is not presented here.
4. Please press the tamper switch at the back of the device for
3-8 seconds
.
5. After
3-5 seconds
, the led will blink three times; you can now release the button.
6. Exclusion should start immediately.
Very quick blinking
on the Z-Wave led on Vera front
panel, followed by
1 second long
, solid light of the sensor’s led indicates successful inclu-
sion.
7. Press and release a Z-Wave button on the back side of a Vera.
8. Wait till Vera
fi
nish recon
fi
guration of the Z-Wave interface. Progress is presented in the
top, right hand side corner of the Vera dashboard.
9. When Vera signals that it wait for the device to wakeup, press and keep temper button
on the device for 3-5 seconds. Once led on the Sensor blinks three times (once per second)
release the temper button.
10. Vera will now con
fi
gure your sensor with standard values and create an association.
Wait about 15-30 sec for Vera to
fi
nish this step.
NOTE:
You should see by now the following screen. There should be three virtual devices.
If you see only one device “_Motion Sensor” that means Vera didn’t refreshed your
dashboard yet. Try to refresh it manually by clicking on the refresh button (see below
in red)
Inclusion (pairing) of the sensor with Z-Wave home network
1. Remove (if there were any) batteries from the sensor, and install them again.
2. Wait
2 minutes
till blinking on the Sensor’s led (two blinks a second) stops.
3.
Press and release
a Z-Wave button on the back side of a Vera. Z-Wave led on front panel
of the Vera should blink slowly. That means that Vera is in Z-Wave
inclusion mode
.
11.Repeat the above steps if the inclusion was unsuccessful.