Generic Installation
2–13
Mode 1 — Jumper In. When the jumper is installed, the
drive operates with a block size of 512 bytes. Use Mode 1
under VMS and ULTRIX operating systems.
The mode select jumper does not affect other operations.
NOTE
The microcode revision reported by the RRD42 disc
drive depends on the mode selected.
Jumpers 0–2
Assign the embedded drive’s ID number by setting the ID
SELECT jumpers in or out. Do not assign the same number
used on another SCSI device.
ID Jumpers
Table 2–1
ID Jumpers 0–2
ID SELECT Jumper Settings
ID
0
1
2
0
Out
Out
Out
1
In
Out
Out
2
Out
In
Out
3
In
In
Out
4
Out
Out
In
5
In
Out
In
6
Out
In
In
7
In
In
In
NOTE
Consult system documentation for further addressing
information.