Expanding Your Server
3-53
SCSI Drive IDs
SCSI bus device addresses are automatically assigned in the hot-swap
drive bay depending on the slot number in which they are installed. The
address jumper on the storage backplane is used to override the default
addresses. The default settings are listed in the following table and can be
set manually to different addresses at your option. The storage backplane
can be configured as two separate SCSI buses or as a single SCSI bus
using a jumper cable. Note that:
•
The SCSI ID addressing is independent of the single or dual SCSI
bus arrangement. Make sure you select unique SCSI IDs for all
SCSI devices on the SCSI bus.
•
You must use a wide SCSI host adapter to set SCSI IDs greater
than seven.
•
Your CD-ROM drive and tape IDs must be set manually. Refer to
your manufacturer’s documentation for information on setting drive
IDs.
NOTE:
You can add narrow SCSI devices to a wide SCSI
bus, however, because of the ID settings, narrow devices
take up two IDs selections on a wide bus.
Содержание PRIORIS ZX 5000 MP
Страница 1: ...P R I O R I S Z X 5 0 0 0 M P S E R V E R U S E R S G U I D E...
Страница 50: ...Expanding Your Server 3 5 DEC00405 2 Figure 3 1 Unlocking and Removing the Side Panels...
Страница 58: ...Expanding Your Server 3 13 DEC00798 A B C D E F G H I J K L Figure 3 5 Power Fan and Control Board Connectors...
Страница 60: ...Expanding Your Server 3 15 DEC00727 2 Figure 3 6 Installing a CPU Module...
Страница 68: ...Expanding Your Server 3 23 A B DEC00729 C Figure 3 10 Installing a SIMM...
Страница 70: ...Expanding Your Server 3 25 DEC00726 3 A Figure 3 11 Replacing the Server Battery...
Страница 72: ...Expanding Your Server 3 27 A DEC00726 4 Figure 3 12 Installing Video Memory...
Страница 78: ...Expanding Your Server 3 33 DEC00730 2 Figure 3 14 Removing a Metal Filler Plate...
Страница 80: ...Expanding Your Server 3 35 DEC00730 4 Figure 3 15 Installing an ISA Expansion Board...
Страница 92: ...Expanding Your Server 3 47 DEC00723 Figure 3 20 Installing Expansion Brackets...
Страница 94: ...Expanding Your Server 3 49 DEC00443 2 A Figure 3 21 Installing a Device Into the Hot Swap Drive Bay...
Страница 102: ...Expanding Your Server 3 57 DEC00733 2 E D C B F A G Figure 3 23 Single Channel SCSI Configuration...
Страница 104: ...Expanding Your Server 3 59 C D E F G H A B DEC00731 2 Figure 3 24 Two Channel SCSI Configuration...
Страница 112: ...Expanding Your Server 3 67 DEC00444 A B Figure 3 27 External SCSI Bus Connections...
Страница 114: ...Expanding Your Server 3 69 DEC00626 Figure 3 28 Connecting an External SCSI Storage Box...
Страница 116: ...Expanding Your Server 3 71 DE C 00609 Figure 3 29 Replacing the Secondary Rear Cooling Fan...
Страница 118: ...Expanding Your Server 3 73 DEC00419 2 Figure 3 30 Installing an Optional Power Supply...
Страница 135: ...Server Security Features 5 4 DEC00405 3 Figure 5 2 Left and Right Side Panel Lock...