Expanding Your Server
3-40
Active negation outputs reduce the chance of data errors by actively driv-
ing both polarities of the SCSI bus and avoiding indeterminate voltage
levels and common-mode noise on long cable runs. The SCSI output driv-
ers can directly drive a 48 mA, single-ended SCSI bus with no additional
drivers.
No additional logic, termination, or resistor loads are required to connect
up to seven 8-bit narrow SCSI devices or up to fifteen 16-bit wide SCSI
devices to each SCSI-2 channel on the main logic board.
SCSI Configuration Guidelines
Your server configuration, SCSI adapter(s), and all SCSI devices must
work together for optimum performance. When installing SCSI devices,
use the following guidelines:
•
The last physical SCSI devices on each end of the SCSI bus must
be terminated. Your server is supplied with the necessary cables
and terminators. If your SCSI device came with terminators in-
stalled, you must remove or disable the terminator from the device
before you complete the installation.
Refer to your SCSI device’s manufacturer documentation for the terminator lo-
cation.
•
Each SCSI device (including the SCSI controller) must be config-
ured with a unique ID number. SCSI controllers usually default to
ID 7. The SCSI CD-ROM drive defaults to ID 5. Use the remaining
IDs 0 through 4 and 6 (narrow and wide adapters) and 8 through
15 (wide adapters only) to configure hard disk drives and other
SCSI devices. Hard disk drives should be configured to start with
SCSI ID 0 and the lower ID numbers. Also, note that the storage
backplane has pre-configured ID settings.
Refer to “SCSI Drive IDs” later in this chapter.
Содержание PRIORIS ZX 5000 MP
Страница 1: ...P R I O R I S Z X 5 0 0 0 M P S E R V E R U S E R S G U I D E...
Страница 50: ...Expanding Your Server 3 5 DEC00405 2 Figure 3 1 Unlocking and Removing the Side Panels...
Страница 58: ...Expanding Your Server 3 13 DEC00798 A B C D E F G H I J K L Figure 3 5 Power Fan and Control Board Connectors...
Страница 60: ...Expanding Your Server 3 15 DEC00727 2 Figure 3 6 Installing a CPU Module...
Страница 68: ...Expanding Your Server 3 23 A B DEC00729 C Figure 3 10 Installing a SIMM...
Страница 70: ...Expanding Your Server 3 25 DEC00726 3 A Figure 3 11 Replacing the Server Battery...
Страница 72: ...Expanding Your Server 3 27 A DEC00726 4 Figure 3 12 Installing Video Memory...
Страница 78: ...Expanding Your Server 3 33 DEC00730 2 Figure 3 14 Removing a Metal Filler Plate...
Страница 80: ...Expanding Your Server 3 35 DEC00730 4 Figure 3 15 Installing an ISA Expansion Board...
Страница 92: ...Expanding Your Server 3 47 DEC00723 Figure 3 20 Installing Expansion Brackets...
Страница 94: ...Expanding Your Server 3 49 DEC00443 2 A Figure 3 21 Installing a Device Into the Hot Swap Drive Bay...
Страница 102: ...Expanding Your Server 3 57 DEC00733 2 E D C B F A G Figure 3 23 Single Channel SCSI Configuration...
Страница 104: ...Expanding Your Server 3 59 C D E F G H A B DEC00731 2 Figure 3 24 Two Channel SCSI Configuration...
Страница 112: ...Expanding Your Server 3 67 DEC00444 A B Figure 3 27 External SCSI Bus Connections...
Страница 114: ...Expanding Your Server 3 69 DEC00626 Figure 3 28 Connecting an External SCSI Storage Box...
Страница 116: ...Expanding Your Server 3 71 DE C 00609 Figure 3 29 Replacing the Secondary Rear Cooling Fan...
Страница 118: ...Expanding Your Server 3 73 DEC00419 2 Figure 3 30 Installing an Optional Power Supply...
Страница 135: ...Server Security Features 5 4 DEC00405 3 Figure 5 2 Left and Right Side Panel Lock...