Digital PRIORIS XL Server
Digital PRIORIS XL Server
Troubleshooting
Troubleshooting
74
74
MCS Logistics Engineering - Nijmegen
MCS Logistics Engineering - Nijmegen
P
R
I
O
R
I
S
X
L
Beep Codes for fatal Errors
(continued)
Beep Code
Error Message
2-1-1
Bit 0 1st 64 KB RAM failure
2-1-2
Bit 1 1st 64 KB RAM failure
2-1-3
Bit 2 1st 64 KB RAM failure
2-1-4
Bit 3 1st 64 KB RAM failure
2-2-1
Bit 4 1st 64 KB RAM failure
2-2-2
Bit 5 1st 64 KB RAM failure
2-2-3
Bit 6 1st 64 KB RAM failure
2-2-4
Bit 7 1st 64 KB RAM failure
2-3-1
Bit 8 1st 64 KB RAM failure
2-3-2
Bit 9 1st 64 KB RAM failure
2-3-3
Bit A 1st 64 KB RAM failure
2-3-4
Bit B 1st 64 KB RAM failure
2-4-1
Bit C 1st 64 KB RAM failure
2-4-2
Bit D 1st 64 KB RAM failure
2-4-3
Bit E 1st 64 KB RAM failure
2-4-4
Bit F 1st 64 KB RAM failure
3-1-1
Slave DMA register failure
3-1-2
Master DMA register failure
3-1-3
Master interrupt mask register failure
3-1-4
Slave interrupt mask register failure
3-2-1
No recovery diskette or disk error
3-2-3
Boot block checksum failure
3-2-4
Keyboard/mouse controller failure
4-2-1
Timer tick interrupt failure
4-2-2
Shutdown failure
4-2-3
Gate A20 failure
4-2-4
Unexpected interrupt in protected mode
4-3-1
RAM failure (above 0FFFFh)
Beep Codes for fatal Errors
Beep Code
Error Message
4-3-3
Interval timer 2 failure
4-3-4
Time-of-day clock failure
4-4-1
Serial port failure
4-4-2
Parallel port failure
4-4-3
Math coprocessor failure