Enter the module’s OBM IP
address, then press Return.
33
DECrepeater 900GM Installation and Configuration
Configuring the Module (Cont.)
[11] Set Out-of-Band Management (OBM) Interface IP Address
NOTE:
This selection is operational only when the module is in
standalone mode (for example, when it is installed into a
DEChub ONE docking station).
This option prompts you to enter the IP address of your out-of-band management
interface.
This option allows you to manage your module through the OBM port located on the
DEChub ONE docking station. You can enable out-of-band management in addition
to normal in-band management. To enable out-of-band management, you need to
assign an OBM IP address (use this option
[11])
and select an OBM port speed
(use option
[12])
from the
DECrepeater 900GM INSTALLATION MENU
. See
DEChub ONE Installation for OBM cabling information.
The following is an example of the dialog associated with this option (user response
is shown in boldface type):
Enter selection : 11
DECrepeater 900GM
SET OUT-of-BAND MANAGEMENT (OBM) INTERFACE IP ADDRESS
Format: The standard 4 octet dotted decimal notation in which
each octet of the address is represented as a decimal
value, separated by a ’.’ character.
example: 16.20.40.156
To delete the IP address, enter 0 in the appropriate
address field.
IP address [none] : 16.20.54.156
Return
Press Return for Main Menu ...