10–2
Thermal Management
29 September 1997 – Subject To Change
Operating Temperature
1
With the heat-sink fan, performance does not depend on system airflow.
Table 10–2 Maximum T
a
at Various Airflows
Airflow (linear ft/min)
100
200
400
600
800
1000
Frequency: 400 MHz, Power: 26.5 W @Vdd = 3.3 V and @Vddi = 2.5 V
T
a
with heat sink 1 (°C)
—
26.8
46.6
51.9
54.6
57.2
T
a
with heat sink 2 (°C)
(includes 52×10 mm fan)
51.9
1
Frequency: 466 MHz, Power: 30.5 W @Vdd = 3.3 V and @Vddi = 2.5 V
T
a
with heat sink 1 (°C)
—
18.0
40.8
46.9
50.0
53.0
T
a
with heat sink 2 (°C)
(includes 52×10 mm fan)
46.9
Frequency: 533 MHz, Power: 35 W @Vdd = 3.3 V and @Vddi = 2.5 V
T
a
with heat sink 1 (°C)
—
—
34.3
41.3
44.8
48.3
T
a
with heat sink 2 (°C)
(includes 52×10 mm fan)
41.3