#347: #347 is Enable/disable soft-limit function for All Axes.If the users need to disable only one axis,he can set the
soft-limit negative value bigger than the positive value,that will make this axis soft-limit invalid.
#448: The user can turn the MPG wheel faster that the controller can move the table. If #448 = 0 the system will store
the pulses so that when the user stops turning the wheel the machine axis will still move. This can lead to a crash. If #448 =
1 when the user stops turning the wheel the system will immediately decelerate and stop
#2028: The FRO and SRO rate also can be changed by MPG.When the value is higer the changing rate is slower.
11) Software limit Parameters(Totally 9 items)
12) MPG Parameters(Totally 8 Items)
#374 Enable software limit
0
BOOL
1/0
0:deceleration; 1:emergency
#375 Soft-limited postion value of X--
Soft-limited postion value of Y--
Soft-limited postion value of Z--
Soft-limited postion value of A--
100
mm
mm
mm
deg
mm
mm
mm
deg
-9999~9999
-9999~9999
-9999~9999
-9999~9999
-9999~9999
-9999~9999
-9999~9999
-9999~9999
0.5~2.0
0.5~2.0
0.5~2.0
0.5~2.0
#376
-400
#377
-20
#378
0
#379 Soft-limited postion value of X++
Soft-limited postion value of Y++
Soft-limited postion value of Z++
Soft-limited postion value of A++
100
#380
400
20
0
#381
#382
Soft-limited stop mode
0
#2030
Soft-limited pre-judgment
coefficient of X
Soft-limited pre-judgment
confficient of Y
Soft-limited pre-judgment
confficient of Z
Soft-limited pre-judgment
confficient of A
1.000
1.000
1.000
1.000
#2032
#2033
#2034
#2035
Para.
Mark
Parameter definition
Default
value
Param
Scope
Param
Unit
Notes
0:Disable; 1:Enable
The group Parameter will trigger the
limit signal of negative direction.
The limit values refer to the
machine coordinates, not the work
piece coordinate.
The group Parameter will trigger the
limit signal of Positive direction. The
limit values refer to the machine
coordinates, not the work piece
coordinate.
When triggered the soft limit,in
order to control the stop speed,we
set this group parameters.
#428 Enable the ESTOP signal on MPG
1
1/0
1/0
1/0
0.001~0.01
1/0
#429 Electric level of ESTOP on MPG
0
#430 MPG interface type
1
0:Seria; 1:Standard
#431 MPG Precision
0.004
1
#432 Standard MPG signal Electric Level
1/0
0
#434 A/B phase signal level on MPG
1/0
This value is bigger,each step of the
handwheel is bigger
The change rate of FRO&SRO by MPG,
the value is higer,the change is slower.
0
#448 MPG control mode
1~100
10
#2028 The % of the change in value per X Pulses
of the Handwheel
Para.
Mark
Parameter definition
Default
value
Param
Scope
Notes
0: Disable,1: Enable
0=Low; 1=High
0=Low; 1=High
0=Low; 1=High
0=Open; 1=Close