A) #220:When we set it as “1”,select the default speed,even when there is no Start Command on G-code file,when you
start the machine spindle will also start;
B) #422:DDCS supports PWM but need to remove a capacitor.The more detailed information please contact us at
5) Coordinate System Parameters(1 Item)
0~5: G54~G59, 6: Mach
#16
current coordinate system
1
BOOL
0~6
6) Spindle Parameters(Totally 9 Items)
rpm
BOOL
BOOL
0:by G code,1:default speed
can be defined
rpm
BOOL
s
0:not response,1:response
BOOL
BOOL
BOOL
#98
#219
#220
#221
#222
#224
#227
#422
#433
maximum spindle speed
Spindle speed selection
If Stop Spindle when pause
default spindle speed
Spindle commands M3/M5 response
Spindle M3/M4/M5 response Duration
Spindle switch Active level
definition of PWM Electric level
PWM rising rate from 0V to 10V
24000
0
0
5777
1
3
1
0
0
99~99999
1/0
1/0
0=No,1=Yes
0=Low,1=High
0=Low,1=High
0=Low,1=High
0=Low,1=High
10~99999
1/0
0~9
1/0
1/0
0~65535
7) Output Signal Parameters(Totally 8 items)
0
0
0
1/0
1/0
0~4294967295
response of M code(M8/M9,M10/M11)
1
BOOL
BOOL
BOOL
BOOL
0=No response; 1=response
0=No response; 1=response
0=Mode 1; 1=Mode 2
delay time of M8/M9
delay time of M10/M11
1
S
1
S
M8/M9 active electric level
1
BOOL
#223
#110
#109
#108
#225
#226
#228
#229 M10/M11 active electric level
1
BOOL
1/0
0~9
0~9
1/0
1/0
M Bus IO default status
M Bus IO command response
M Bus IO Initialization strategy
Para.
Mark
Parameter definition Default
value
Parameter
Unit
Parameter
Scope
Notes
Para.
Mark Parameter definition
Default
value
Param
Unit
Param
Scope
Notes
Para.
Mark
Parameter definition
Default
value
Param
Unit
Param
Scope
Notes
Spindle PWM or voltage signal full
range is corresponding to speed
The acceleration time to full speed
is #433*0.0005s