Rotating and Replacing the Discriminator Pad
Note:
The discriminator pad is user-replaceable. If the pad is worn on one surface, it can be rotated to an
unworn side. If all sides of the pad are worn, it can be replaced. This is typically only needed for scanners that
have been in service for longer periods of time, or for teller windows and higher-volume remote deposit
settings. (PN: 155177-01 - available at www.digitalcheck.com)
Step 1:
Open the center cover and the feed roller door to provide access to the discriminator pad. See the
Accessing the TellerScan TS500
section for additional information.
Step 2:
Lift or pull up on the discriminator pad to remove. There are no tools required for removal.
Step 3:
Rotate the pad to an unworn side. If all sides of the pad are worn replace with a new discriminator pad.
Reinsert the pad into the scanner, push down completely, and close the center cover and feed roller door.
Discriminator Pad
Rotate pad 90°
Worn side of pad