DR5013 DIGIREVERSE
P 32
www.digikeijs.com
® R
-
Bus, B
-
Bus
are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS
-
Bus is a trademark registered in the name of Lenz
Stand 2021
-
07
-
06
DR5013 Check connection:
This allows you to test whether S0, S1, S2 and S3 have been wired correctly:
1)
Switch off track voltage.
2)
Remove all locomotives and other loads from the sensor tracks (
S0, S1, S2, S3
).
3)
Switch on track voltage.
4)
Place the locomotive on the sensor track
S0
and observe whether the
blue
LED
lights up
.
If the
blue
LED does not light up, check the wiring or the address assignment in the app of
S0
!
5)
Remove locomotive from sensor track
S0
.
6)
Place the locomotive on the sensor track
S1
and observe whether the
blue
LED
lights up
.
If the
blue
LED does not light up, check wiring of
S1
!
7)
If both tests (4. & 6.) show that the
blue
LED is lit, the sensor tracks
S0
and
S1
are wired cor-
rectly.
The next step is to perform the function test with the sensor tracks S2 and S3.
can be carried out.
8)
Place the locomotive on the sensor track
S3
and observe whether the
blue
LED is
not illumi-
nated
. If the
blue
LED
lights up
, check the wiring or the address assignment in the app of S3!
9)
Remove the locomotive from the
S3
sensor track.
10)
Place the locomotive on the sensor track
S2
and observe whether the
blue
LED is
not illumi-
nated.
If the
blue
LED lights up, check the wiring of
S2
!
11)
If both tests (9. & 10.) show that the
blue
LED is not lit, the sensor tracks
S3
and
S2
on the
DR5013
are wired correctly.
12)
At the end of the test series, place the locomotive on the sensor track
S0
and drive in direc-
tion
S1
over the double track separation point into the reversing loop track (
T
).
If the
blue
LED
does not
light up or a
short circuit
is triggered at the DR5013, the track con-
nections at the track input of the DR5013 must be replaced.
13)
Finally go through the complete reversing loop again to test the connection completely:
S0
-
>
S1
-
> T
-
> S2
-
> S3
6.1 Commissioning instructions DR5013 with sensor tracks
S0,S1,S2,S3 (without connection to PC)
To check the connection of the DR5013 without a USB connection to the PC, use this procedure. This can be used to test if the wiring is correct and there is no
error.
S0
S1
S3
S2
Blue
LED Indication of polarity of the
reversing loop track
S0
S1
S2
S3
4
6
8
10
12
13