4.8 Properties of sensor tracks

 

The properties of the sensor tracks and the feedback number are assigned to the reversing loop here.

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

1)

 

Switch

-

off delay Feedback in 

ms.

 

2)

 

turnout mode

 

Mode how the turnout address is used.

 

Off

 

No action.

 

3)

 

Follow

 

The polarity of the reversing loop follows the position of the 

 

   

turnout.

 

Set

 

S1 and S2 set the turnout.

 

Both

 

Both (Follow, Set) options are considered

 

4)

 

Turnout status

 

Condition of the turnout when the reversing loop is in its initial position.

 

5)

 

Closed

 

Position of the turnout straight

 

6)

 

Thrown

 

Position of the turnout curved

 

7)

 

Feedback number Sensor track 1 (

S1

)

 

(Sensor track for polarity switching) 

 

8)

 

Feedback number Sensor track (

S0

)

 

(Reversing loops Enter entry indicator 

*optional* 

if not used Feed-

back indicator number "0".)

 

10

 

11

 

6)

 

turnout address Entrance turnout of the reversing loop

 

7)

 

Feedback number Sensor track (

S3

)

 

(Reversing loops Enter entry indicator 

*optional* 

if not used Feedback in-

dicator number "0".)

 

8)

 

Feedback number Sensor track 2 (

S2

)

 

(Sensor track for polarity switching) 

 

9)

 

Feedback number Reverse loop track (

T

)

 

10)

 

Accept current settings.

 

11)

 

Cancel

 

12)

 

First switch (1.magnetic article address) to be addressed.

 

setting:

 

0 = Roco® (shift of magnetic article add4)

 

1 = Magnetic article addresses Standards

-

compliant to RCN 213

 

(

default setting!)

 

13)

 

turnout position indicator

 

14)

 

These arrows symbolize the entry or exit into the reversing loop.

 

15)

 

These points indicate which feedbacks have triggered.

 

12

 

13

 

14

 

15

 

15

 

Содержание DR5013 DIGIREVERSE

Страница 1: ...n GmbH XpressNet and RS Bus is a trademark registered in the name of Lenz Stand 2021 07 06 DR5013 DIGIREVERSE Instruction manual 2021 07 06 Copyright 2005 2018 digikeijs the Netherlands All rights reserved No information images or any part of this document may be copied without the prior written permission of Digikeijs ...

Страница 2: ...factory settings 15 4 4 Updating the Soft and Firmware 16 4 5 Firmware Versions 17 4 6 LocoNet Features 18 4 7 0 Module Properties Part 1 19 4 7 1 Module Properties Part 2 20 4 8 Scripting with DR Script 21 4 9 Properties of sensor tracks 22 4 10 Global Detector Features 23 5 0 Connection examples 24 5 1 DR5013 Connection for short circuit detection 25 5 2 DR5013 Connection for short circuit detec...

Страница 3: ...anty ATTENTION The warranty is void if the housing of the product is opened 1 3 Legal information Printing errors and mistakes technical or other changes as well as changes in the availability of individual products are expressly reserved Data and illustrations are non binding All changes to hardware firmware and software are reserved We reserve the right to change the design of the product the so...

Страница 4: ...circuit message can be output via LocoNet or via the SHORT output of the module An integrated Railcom detector for address evaluation and POM reading is also included An electronic high speed MOSFET relay with 3 ampere load capacity for switching over ensures absolutely trouble free and wear free reversing of polarity of the reversing loop There is also a USB port for configuration and firmware up...

Страница 5: ...t circuit detected 7 FB CS Track Ground brown 8 FB CS Feedback external current sensor Connection of feedback 1 16 to DR4088CS loop track 9 FB GND Feedback external switches to GND loop track 10 FB GND Connection C on DR4088GND 11 LocoNet connection 1 12 LocoNet connection 2 13 Track Input K 14 Track Input J 15 USB Status LED green RX red TX 16 USB 2 0 connection 1 2 11 3 4 5 6 7 8 12 13 14 9 10 1...

Страница 6: ...e name of Lenz Stand 2021 07 06 3 0 CONFIGURATION SOFTWARE ATTENTION NEVER connect the DR5013 to the PC via USB when the TRACK INPUT of the DR5013 is connected to the TrackOut main track or programming track of the central unit This can destroy the DR5013 the central unit and or the USB interface in the PC The USB connection to the PC must only be used to configure the DR5013 ...

Страница 7: ... To do this you will need the supplied USB cable a so called USB A to USB mini cable System requirements Intel Pentium or AMD Athlon 64 processor Microsoft Windows 7 with Service Pack 1 Windows 8 1 or Windows 10 1 GB RAM for 32 Bit 2 GB RAM for 64 Bit 100 MB free hard disk space Monitor with a resolution of 1 024 x 768 1280 x 800 recommended 3 2 Download Software Do not connect the DR5013 to the P...

Страница 8: ...egistered in the name of Lenz Stand 2021 07 06 3 Important Do not connect the DR5013 to the PC until the software and driver ha ve been successfully installed 3 3 Install software After you have successfully downloaded the software the installation can be started by double clicking on the DR5013xx exe file Make sure that you have administrator rights on your PC ...

Страница 9: ...enbahn GmbH XpressNet and RS Bus is a trademark registered in the name of Lenz Stand 2021 07 06 The following screen appears after a few seconds Click Next If you want to change the location of the software you can do so on the next screen However it is recommended to leave the settings as they are and click Next ...

Страница 10: ...k registered in the name of Lenz Stand 2021 07 06 Now follows a short overview of the settings Click on Install if you agree Now the configuration software will be installed and Windows will ask you a few times if you trust Digikeij s software When all this is complete the last screen appears Press Finish and the drivers and configuration program are installed ...

Страница 11: ...oftware until the following steps have been performed First connect the PC with the supplied USB cable and then with the DR5013 Windows detects the new hardware and installs the drivers Wait until this process is completed and you receive a message from Windows that the hardware has been installed correctly Windows will assign and reserve a COM port to the DR5013 The numbering of the COM ports dep...

Страница 12: ...rogramming track of the central unit This can destroy the DR5013 the central unit and or the USB interface in the PC The USB connection to the PC must only be used to configure the DR5013 All pictures shown here usually show the factory settings of the DR5013 However some pictures show more information than is available in the factory settings which has the reason to clarify which options and sett...

Страница 13: ...istered in the name of Lenz Stand 2021 07 06 4 1 Overview Configuration Software The various options can be easily accessed by clicking on the respective connections 1 Properties of sensor tracks 2 Features Global Detector 3 USB Features Firmware Upgrade 4 Exit software 5 DR5013 Serial number 6 Module Properties 7 LocoNet Features 8 instruction manual 4 6 7 5 3 1 2 ...

Страница 14: ...hn GmbH XpressNet and RS Bus is a trademark registered in the name of Lenz Stand 2021 07 06 4 2 USB 2 0 Features 1 The selected DR5013 has been connected via USB and the serial number is read 2 COM port number for the Dr Command protocol 3 Update the firmware of the DR5013 4 Reset to factory settings 5 Cancel 1 2 3 4 5 ...

Страница 15: ... GmbH XpressNet and RS Bus is a trademark registered in the name of Lenz Stand 2021 07 06 4 3 Restoring the factory settings It is possible to reset the DR5013 settings to the factory defaults The USB menu in the configuration software allows you to activate the reset which resets the DR5013 settings to factory defaults ...

Страница 16: ...Settings function You must first install the latest version of the configuration software before the current firmware update is available Method 1 Disconnect the DR5013 from the PC 2 Download the new version from our website 3 Install the configuration software 4 Connect the DR5013 to the USB cable and the PC 5 Open the configuration software 6 Go to the USB2 0 menu 7 Use the Update DR5013 button ...

Страница 17: ...n the name of Modelleisenbahn GmbH XpressNet and RS Bus is a trademark registered in the name of Lenz Stand 2021 07 06 4 5 Firmware Versions Version date Beschreibung 1 0 0 01 11 2018 First beta version for beta testers 1 0 0 10 10 2018 First instructions 1 0 0 11 11 2018 Connection examples ...

Страница 18: ... There is a restriction of the address ranges locomotive address or block address when the derailing direction is sent MULTI_SENSE_Long The new OPC_MULTI_SENSE_L command is used No restriction of the address ranges MULTI_SENSE_Both Both commands Long and Standard are transmitted to the central unit 4 RailCom Sense direction Here you can select how the derailment direction is reported to the contro...

Страница 19: ...t message via LocoNet CP_OFF Send short circuit message via LocoNet OPC_PEER_XFER Send short circuit message via LocoNet Uhlenbrock Specification Both Send both messages via LocoNet 9 Switch the track voltage on again automatically after a short circuit 10 Waiting time after a short shot before the track voltage is reactivated 11 Module Setting Export Import 12 Accept current settings 13 Cancel 14...

Страница 20: ...ue can be set here See example 5 Report the signal quality of the Railcom messages to the control cen tre The messages are reported by the decoder in 0 All commands have arrived track or locomotive clean 100 of the commands have not arrived track or locomotive dirty 4 6 1 Module Properties 6 7 6 All QoS messages below this value are not reported to the central unit 7 A Delta value can be set here ...

Страница 21: ...Dr Script you have the possibility to control even complex processes with the help of a product of the DR50xx series Further information about Dr Script can be found in the separate documentation 1 Open script If this check mark is set 2 If this box is checked the last script called is automatically started after the DR50xx has been started 3 Select printer 4 Call help Debug mode 5 Debug mode 6 St...

Страница 22: ...nout straight 6 Thrown Position of the turnout curved 7 Feedback number Sensor track 1 S1 Sensor track for polarity switching 8 Feedback number Sensor track S0 Reversing loops Enter entry indicator optional if not used Feed back indicator number 0 10 11 6 turnout address Entrance turnout of the reversing loop 7 Feedback number Sensor track S3 Reversing loops Enter entry indicator optional if not u...

Страница 23: ... loop The Global Detector comprises the sections S1 S2 and T of the reversal loop 1 Detector input on the module If a check mark is removed here the corresponding detector is deactivated 2 Feedback address of the normal occupancy detector current sensor 3 Block number linked to the detector output Railcom detector 4 Switch off delay of the feedback devices 5 The DR5013 detects the track direction ...

Страница 24: ...y sufficient Basically the DR5013 module has three different modes operating modes 1 Current difference measurement also known as short circuit detection Example 5 1 5 2 2 Sensor controlled short circuit free with 4 sensor track sections Example 5 3 3 Turnout controlled short circuit free the turnout position controls the polarity of the reversing loop or the reversing loop controls the turnout Ex...

Страница 25: ...the locomotive crosses the separation point at the exit the DR5013 detects this and switches the polarity of the reversing loop to match the polarity of the exit The turnout must be switched manually or via a control pro gram It may be necessary to add switching decoders and further feedback modules for switch control and evaluation of the external feedback connections No changes to the DR5013 fac...

Страница 26: ...coNet with the integrated occupancy detector and can for example be evaluated with a control program At the same time the Railcom data of the locomotive address QoS mes sages etc are read out in the entire reversing loop track and also reported to the control centre The locomotive drives in the direction of the exit As soon as the locomo tive crosses the separation point at the exit the DR5013 det...

Страница 27: ... detector and can be evaluated for example with a control program At the same time the Railcom data of the locomotive address QoS messages etc are read out in the entire reversing loop track S1 S2 Track and also reported to the central station The locomotive reaches sensor track 2 S2 The DR5013 now recognizes that the locomotive is on its way to the exit of the reversing loop The polarity of the r...

Страница 28: ... the same time the Railcom data of the locomotive address QoS messages etc are read out in the entire reversing loop track S1 S2 Track and also reported to the control centre The locomotive reaches sensor track 2 S2 The DR5013 now recognizes that the locomotive is on its way to the exit The polarity of the reversing loop is switched according to the polarity of the exit In addition the DR5013 can ...

Страница 29: ...ed to the central unit andcan be evaluated for example with a control program The locomotive reaches sensor track 2 S2 The DR5013 now detects that the locomotive is on its way to the exit and switches the polarity of the reversing loop accord ing to the polarity of the exit In this example the turnout cannot be switched by the DR5013 because there is no connection via Loconet to the central unit H...

Страница 30: ...FB current sensor GND signal to ground and a short circuit signal of the reversing loop can be reported to an external feedback Emergency stop short circuit mes sage to a digital system that has a CDE booster connection Track Out digital central Occupancy message of the rever sing loop as current sensor DR4088xx CS Occupied signal of the reversing loop against ground DR4088xx GND Attention Simulta...

Страница 31: ...the configuration tool must be started Note A connection via USB to the DR5000 or any other digikeijs device connected via USB must be disconnected first If this note is observed the test can be carried out without any problems even with active track voltage Place the locomotive on the sensor track S2 The feedback S2 in the app now shows the assignment yellow dot If no busy message is displayed th...

Страница 32: ...3 and observe whether the blue LED is not illumi nated If the blue LED lights up check the wiring or the address assignment in the app of S3 9 Remove the locomotive from the S3 sensor track 10 Place the locomotive on the sensor track S2 and observe whether the blue LED is not illumi nated If the blue LED lights up check the wiring of S2 11 If both tests 9 10 show that the blue LED is not lit the s...

Отзывы: