DR4024 Servodecoder
P 9
www.digikeijs.com
® R-Bus, B-Bus
are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
Stand 2018.10.22
3.3 Programming of CV's via POM
(main track programming)
Make sure the DR4024 is powered from the decoder's power connector. The
green LED
next to the power connector must now light up permanently. It is best
to use a switching power supply with at least 12V DC output voltage and 3A output power. The signal connec on of the decoder must be connected to the main
track output of your control panel! The DR4024 cannot be read out via Railcom®!
1.
A locomo1ve with
address 9999
and
128 speed steps DCC
must be defined in the central unit, mul1 mouse, app etc..
The DR4024 can be programmed similar to a locomo1ve decoder using this locomo1ve address.
2.
Select the locomo1ve with the address 9999 at the central sta1on, mul1 mouse, app, etc.
Switch the func1on
F0
(light) on and off again to ac1vate the locomo1ve in the control panel.
3.
Press the programming bu2on on the DR4024. The red LED is now lit con1nuously and indicates that the DR4024 is in "programming mode".
4.
Select the CV Programming (POM) func1on in your control panel, app or handset.
(For further informa on on CV byte or CV bit programming, please refer to the opera ng instruc ons of your control panel)
5.
Now the desired CV value can be wri2en to the DR4024 with the respec1ve func1on Write POM of the central, app or handset controller.
6.
An infinite number of CV's can be sent one aJer the other to the DR4024.
7.
To exit the programming mode of the DR4024, the programming bu2on must be pressed again.
The red LED goes out and indicates that the programming mode has been terminated.
The
start address
(turnout address) for the DR4024 is always assigned via a
turnout command
and
not via the CV1
!!!
If the CV1 is nevertheless wri2en with an address, the decoder can
no longer be programmed with the locomo ve address 9999!
Supply voltage
12-18V DC/AC
Recommended min.
12V DC 2A
A;en on!!!
If for any reason the address 9999 required for programming
has been changed in the DR4024, the reset must be carried out
via the programming track, point 3.6.