DR4024 Servodecoder
P 20
www.digikeijs.com
® R-Bus, B-Bus
are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
Stand 2018.10.22
7.0 CV Table
CV
CV Defini on
Range
Value
7
Decoder Version
13
8
Manufacturer ID
Value '8' resets the decoder to factory seBngs.
42
17
Long address
high byte
192-255
231
18
Long address
low byte
0-255
15
47
Presets / Presets 0-3
(this CV can only be wri2en a read out is not possible!)
0 – 3
0
The DR4024 servo decoder has four presets to make programming easier. Each preset configures the DR4020 so that you do not have
to change CVs manually. For detailed informa1on on these presets, see page 24.
112 Flashing frequency for the switching outputs
with bit 7 ac1ve in CV117 - CV120. Value 20 is 90x per minute.
0-255
20
113
-
116
CVs 113-116 have the same func1on as servos 1-4.
0-255
2
Value
Funk on
0
Default seBng 0 > 4 servos (1-4) and 4 separate switching outputs (5-8)
(8 addresses)
1
Default seBng 1 > 4 servos (1-4) with linked switching outputs (1-4)
(4 addresses)
2
Default seBng 2 > 4 servos with mass simula1on (1-4) and 4 separate switching outputs (5-8)
(8 addresses)
3
Default seBng 3 > Level crossing with flasher, 2 barriers and mass simula1on
(2 addresses)
Bit
Funk on
Value
0-3
Sets the servo step size.
Value 15 is the fastest;
Value 0 is the slowest.
2
0-15
4-7
Sets the servo step speed.
Value 15 is the smallest and Value 0 is the largest. 0 stands for 50 steps per
second. 1 = 25/s, 2 = 12/s, 3 = 5/s, 4 = 4/s. etch... MaximumValue 15 = 1
step / second.
The last seBng in combina1on with bits 0-3 switched to 0 means that the
servo switches between the two extreme posi1ons in 126 seconds!
0
(0-15)
*16