Setting up of the altimeters
The instrument is equipped with 3 altimeters:A1 is readable on the
screen 1, A2 and A3 are readable on the creen 3. It is possible to
zero A2 and A3 pressing
.
When the instrument has been switched on, press the key
and
the following image will appear on the screen:
screen 1 Rec
screen 2 Alt
screen 3 Set 1
Pressing
you can enter the various sub-menus in succession:
choose the sub-menu Alt. Press
, on screen 1 A1 will appear..
The blinking indicates that this value is ready to be adjusted, pressing
to increase it and pressing
to decrease it (a steady pressure
on the key makes this operation faster).
Once you have selected the required value, press
to confirm.
Now you can do the same operation for the values A2 and A3.
Then press
to exit the sub-menu.
Averager and acoustic variometer sensitivity threshold
setting
Press
.
Press
twice to choose the submenu Set. Pressing
the value on the screen 2 blinks: pressing
or
you can adjust
the climb rate that the audio will begin to sound at. If you, for
example, select the value 0.3, the acoustic variometer will signal
only altimetric changes higher than 30 cm/sec. After having selected
the requested limit, press
to confirm. Do the same operation to
select the descent limit. Pressing
again you have access to the
averager, which can be selected for delays up to 30 seconds,
pressing
or
(Ex.: if I choose sec 15 the analogue and sound-
variometer will continue to signal the instantaneous altimetric
change, while the digital variometer will indicate the altitude gain
or loss over the last 15 seconds).
Once you have selected the delay press
to confirm. Escape
.
Adjusting the units
The readings can be displayed in metres and Km/h or in feet and
Mph. To change the measurement system you have to operate in
the following way. Press
, press
twice, then press
four
times. Press
or
to select the height in metres or feet. Confirm
pressing
.
Italiano
English
Français
Deutsc
h
Содержание VL 100 RACER