Datasheet of 301-1141-01 - WATCHPORT TEMP SENSOR 
Contact us: [email protected] Website: www.integrated-circuit.com

Watchport Installation Guide (90000406 Rev. H) – Page 24 

UL/CSA Safety Information 

This  device  complies  with  the  requirements  of 
following safety standards below:  

UL 1950, 3rd edition 
CSA No. 950 

Quality Manager 
Austin, Texas 
February 2007 

 

 

 

China RoHS statement: 

 

The Table of Toxic and Hazardous Substances/Elements and their Content shall apply to any product 
covered by this manual and labeled with the following symbol: 

 

 

The Table of Toxic and Hazardous Substances/Elements and their Content 

as required by China’s Management Methods for the Control of Pollution from Electronic Information Products 

 

 

Toxic and Hazardous Substances or Elements 

(

有毒有害物

有毒有害物

有毒有害物

有毒有害物质

质或元素

或元素

或元素

或元素

) 

Part Name 

(

部件名称

Lead 

(Pb) 

(

Mercury 

(Hg) 

(

Cadmium 

(Cd) 

(

Hexavalent 

Chromium 

(Cr (VI)) 

(

六价铬

Polybrominated 

biphenyls 

(PBB) 

(

多溴联苯

Polybrominated 

diphenyl ethers 

(PBDE) 

(

多溴二苯醚

301-1002-08 

 

 

 

 

 

 

 

O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this 
part is below the limit requirement in SJ/T 11363-2006. 

表示该有毒有害物质在该部件所有均质材料中的含量均在

SJ/T11363-2006 

标准规定的限量要求以下

.

 

 
X:  Indicates  that  this  toxic  or  hazardous  substance  contained  in  at  least  one  of  the  homogeneous 
materials used for this part is above the limit requirement in SJ/T 11363-2006. 

示该有毒有害物质至少在该部件的某一均质材料中的含量超出

SJ/T11363-2006 

标准规定的限量要求

.

 

 

 

                            27 / 28

                            27 / 28

Содержание Watchport/A

Страница 1: ...Excellent Integrated System Limited Stocking Distributor Stocking Distributor Click to view price real time Inventory Delivery Lifecycle Information Click to view price real time Inventory Delivery Li...

Страница 2: ...EMP SENSOR Contact us sales integrated circuit com Website www integrated circuit com Watchport USB ENVIRONMENTAL MONITORING APPLIANCES Installation Guide Sensor Models Watchport H Watchport P Watchpo...

Страница 3: ...AVI Drivers 3 Installing Watchport Sensor Drivers 4 Cabling Watchport 6 Watchport Camera Products 6 Watchport Sensor Products 6 Installing Watchport Manager 8 Updating Base Unit Firmware 8 Using the W...

Страница 4: ...Watchport Manager Watchport Manager sends phone email or beeper alerts and enables easy device integration without additional software development Watchport products consist of the following parts Th...

Страница 5: ...the Found New Hardware screen for the Watchport USB Loader software appears choose option a or option b a Specify the location of the drivers and click Next b Install from a list or specific location...

Страница 6: ...edia type the location path or browse to locate the drivers on your CD ROM drive Use one of these methods to locate the drivers and click Next 4 Windows may warn that the software has not passed Windo...

Страница 7: ...rd appears select Install from a list or specific location Advanced and click Next 4 Select Search for a suitable driver for my device and click Next 5 Select Specify a location and click Next 6 Type...

Страница 8: ...allation is complete 3b If you are replacing existing Edgeport drivers Follow the on screen instructions Note that before beginning the installation of the drivers all applications with open ports mus...

Страница 9: ...ft audio white connectors with the corresponding receptacles on your video device When using a standard S Video cable match the S Video black right audio red and left audio white with the correspondin...

Страница 10: ...its To extend your cable we recommend that you use CAT 5 twisted pair cable and follow the wiring in Table 1 Your color assignment may vary and you will need to adjust the tables accordingly Connect o...

Страница 11: ...installing click Yes 6 Click OK to complete installation You can open the Watchport Manager from the Start Programs menu Updating Base Unit Firmware This section applies to Watchport Sensor base unit...

Страница 12: ...mode Watchport A and Watchport D The first type of sensing devices uses ASCII commands All ASCII commands sent to the sensing device must be terminated with a carriage return character CR Multiple co...

Страница 13: ...A CR C CR Calibrates the sensor OK CR A CR Reflects the current acceleration n nngX m mmgY CR U CR Reads the raw axis values These are the values that would be read if the C command were never execut...

Страница 14: ...CR Gives the percentage relative humidity 38 CR T CR Gives temperature in Celsius 22 2500C CR TC CR Also gives temperature in Celsius 22 2500C CR TF CR Gives temperature in Fahrenheit 72 0000F CR TF C...

Страница 15: ...up cover Push firmly to close Red LED This light indicates that the sensor is receiving some reflection of its signal but not enough to trigger the amber light A persistent red light may mean that the...

Страница 16: ...ctor that is if an object comes within range the sensor will raise and then lower its DSR signal The default mode is Proximity Watchport D Commands Command Description Return Value CR Tells about the...

Страница 17: ...mperature in Celsius 22 2500C CR TC CR Also gives temperature in Celsius 22 2500C CR TF CR Gives temperature in Fahrenheit 72 0000F CR TF CR Repeats the TF commend every 3 4 seconds until the next key...

Страница 18: ...Watchport W uses an RS 232 modem signal interface and gives a binary output as frequently as 100 times per second If using the Watchport Manager the sensor is defaults to 1 read per 3 seconds DCD hig...

Страница 19: ...ll Windows Operating Systems The Edgeport configuration utility program edgeport exe allows you to manage the serial ports of your Watchport product Note that with Windows NT you must have administrat...

Страница 20: ...a user friendly Device Name This capability is particularly helpful if you have more than one device Port Flags Configure performance options and special functionality on a per port basis Low Latency...

Страница 21: ...n transmitted out of the Edgeport device before completing the write When the Fast Writes flag is set we complete the write even if data is still buffered in the driver and the Edgeport device Fast Re...

Страница 22: ...T TEMP SENSOR Contact us sales integrated circuit com Website www integrated circuit com Watchport Installation Guide 90000406 Rev H Page 19 Test Ports Perform a confidence test on the internal workin...

Страница 23: ...seconds between updates of this window This is also the number of seconds between each entry in the log file To create a log file click the Start Logging button and enter a filename for the log file...

Страница 24: ...hich physical USB port a converter is plugged into it will maintain its assigned COM port numbers 2 Assign COM ports based on physical USB port In this mode the driver identifies a converter based on...

Страница 25: ...e above copyright notice and restricted rights notice Use copying and or disclosure of the programs is strictly prohibited unless otherwise provided for in the license agreement Federal Communications...

Страница 26: ...01 9018 01 Product Name Watchport Clamp Mount Model Number s 301 9019 01 Product Options All conforms to the relevant EU Directives listed here EMC Directive 2004 108 EC Low Voltage Directive 2006 95...

Страница 27: ...led with the following symbol The Table of Toxic and Hazardous Substances Elements and their Content as required by China s Management Methods for the Control of Pollution from Electronic Information...

Страница 28: ...ated circuit com Watchport Installation Guide 90000406 Rev H Page 25 Digi International 11001 Bren Road East Minnetonka MN 55343 digi info digi com www digi com Corporate Headquarters 952 912 3444 877...

Отзывы: