90030500B
Configuring Modem Connections
Page 127
• Many modems have external or internal jumpers that override the normal
operation of DTR, DCD, RTS and CTS. Check the settings of these jumpers on
your modem by referring to your modem manual.
• You can watch the LEDs on the PortServer II front panel to monitor correct
modem operation. In particular, verify that DCD is off when the modem is not
connected. Verify that the modem does not answer a call when DTR is low, and
hangs up when DTR is dropped.
Configuring the Modem Connection
1. Set the relevant PortServer II serial port to the highest speed that the modem can
accept without data corruption, by entering the following command:
set line baud=<speed> range=<ports> [options]
<speed>
is the baud rate of the serial port, which can only be set to certain legal
values (refer to
set line
in the Command Reference Guide).
<ports>
speci-
fies the port(s) you are setting. [
options
] are control and parity settings and
must correspond to your modem’s settings.
For example, to set serial port 4 to 2400 baud and tell it to ignore parity errors,
enter:
set line baud=2400 range=4 error=ignore
Note:
Remember that this command sets the PortServer II-to-Modem connec-
tion, not the speed at which the modem communicates over the telephone
lines. If you are uncertain of the best value, we suggest you try the default
setting of 9600 baud. If this does not allow reliable data transfer, lower
this value until you obtain satisfactory results. If the default setting allows
reliable transfer, increase the value until you obtain the highest setting
that allows reliable transfer.
2. If you have not already done so, set the serial port for the modem device type, by
entering:
set port dev=<modem_type> range=<ports>
<modem_type>
may be
mio
for a bidirectional modem,
min
for an input-only
modem, or
mout
for an output-only modem.
<ports>
specifies the port(s) you
are setting. For example, to use a bidirectional modem on port 4, enter:
set port dev=mio range=4
Содержание PortServer II
Страница 1: ...8VHU V XLGH PortServer II QWHOOLJHQW 1HWZRUN RPPXQLFDWLRQV DQG 7HUPLQDO 6HUYHU ...
Страница 2: ......
Страница 4: ...90030500B Page ii ...
Страница 20: ...Page xviii About this User s Guide 90030500B ...
Страница 74: ...Page 54 Installation 90030500B ...
Страница 106: ...Page 86 Configuring Terminals 90030500B ...
Страница 144: ...Page 124 Configuring WAN Connections 90030500B ...
Страница 168: ...Page 148 Configuring TCP IP Routing 90030500B ...
Страница 180: ...Page 160 Configuring SNMP 90030500B ...
Страница 206: ...Page 186 Remote Configuration 90030500B ...
Страница 264: ...Page 244 Digi Support Services 90030500B ...
Страница 270: ...Page 250 Glossary 90030500B ...