background image

CR4110 Installation Guide 

Special Notes on CDMA/EV-DO Wireless Safety 

Digi  International  products  are  designed  to  the  highest  standards  of  safety  and 
international  standards  compliance  for  the  markets  in  which  they  are  sold.  However, 
wireless products contain radio devices which require specific consideration. Please take 
the  time  to  read  and  understand  the  following  guidance.  Digi  International  assumes  no 
liability for an end user‟s failure to comply with these precautions. 

 

Wireless  routers  incorporate  a  wireless  radio  module.  Users  should 
ensure  that  the  aerial  is  positioned  at  least  1  metre  away  from 
themselves and other persons in normal operation. 

When in a hospital or other health care facility, observe the restrictions on 
the  use  of  mobile  phones.  Do  not  use  the  router  in  areas  where 
guidelines  posted  in  sensitive  areas  instruct  users  to  switch  off  mobile 
phones. Medical equipment may be sensitive to RF energy. 

The  operation  of  cardiac  pacemakers,  other  implanted  medical 
equipment and hearing aids can be affected by interference from cellular 
terminals such as the wireless routers when placed close to the device. If 
in  doubt  about  potential  danger,  contact  the  physician  or  the 
manufacturer  of  the  device  to  verify  that  the  equipment  is  properly 
shielded.  Pacemaker  patients  are  advised  to  keep  the  wireless  router 
away from the pacemaker while it is on. 

 

Wireless  routers  must  NOT  be  operated  on  aircraft.  The  operation  of 
wireless appliances in an aircraft is forbidden to prevent interference with 
communications systems. Failure to observe these instructions may lead 
to  the  suspension  or  denial  of  cellular  services  to  the  offender,  legal 
action, or both. 

 

As  with  any  electrical  equipment,  you  should  not  operate  your  wireless 
router in the presence of flammable gases, fumes or potentially explosive 
atmospheres.  Radio  devices  should  not  be  used  anywhere  that  blasting 
operations are taking place. 

 

Wireless  routers  receive  and  transmit  radio  frequency  energy  while 
switched on. Remember that interference can  occur if it is used close to 
TV  sets,  radios,  computers  or  inadequately  shielded  equipment.  Follow 
any  special  regulations  and  always  switch  off  your  wireless  router 
wherever  forbidden  or  when  you  suspect  that  it  may  cause  interference 
or danger. 

 

SOS  IMPORTANT! 

–  Wireless  routers  operate  using  radio  signals  and 

cellular  networks  cannot  be  guaranteed  to  connect  in  all  possible 
conditions.  Therefore,  you  should  never  rely  solely  upon  any  wireless 
device for life critical communications. 

Содержание CR4110

Страница 1: ...C C R R 4 4 1 1 1 1 0 0 4000 Series Router Wireless CDMA EV DO 450 Rev A Installation Guide ...

Страница 2: ...Electrical and Electronic Equipment 2002 96 EC directive has been introduced to ensure that electrical electronic products are recycled using the best available recovery techniques to minimise the impact on the environment This product contains high quality materials and components which can be recycled At the end of its life this product MUST NOT be mixed with other commercial waste for disposal ...

Страница 3: ...r connecting non approved antennas or power supplies may damage the unit cause interference or create an electric shock hazard and will void your warranty 4 Do not attempt to repair the product The unit contains no electronic components that can be serviced or replaced by the user Any attempt to service or repair the unit by the user will void the product warranty 5 The CR4110 is designed for indo...

Страница 4: ...otential danger contact the physician or the manufacturer of the device to verify that the equipment is properly shielded Pacemaker patients are advised to keep the wireless router away from the pacemaker while it is on Wireless routers must NOT be operated on aircraft The operation of wireless appliances in an aircraft is forbidden to prevent interference with communications systems Failure to ob...

Страница 5: ...11 CDMA 1xEV DO 450 Release A wireless capability The CR4110 may be purchased with an optional GPS Global Positioning System module Note You will not be able to use the router for remote communication until you have subscribed to a suitable wireless network service Package Contents When you receive the router carefully unpack it and check the contents These should include CR4110 router system unit...

Страница 6: ... many standard LAN and Internet protocols such as PPP the CR4110 provides a combination of powerful but easy to use configuration management and diagnostic tools This makes it a simple and cost effective solution for migrating existing terminal or telemetry equipment which use wired networks PSTN ISDN etc to wireless operation 1 1 Front Panel Features The front panel of the unit incorporates the U...

Страница 7: ...tors labelled SIGNAL illuminate to indicate the GSM signal strength as follows None illuminated 116 dBm effectively no signal 1 LED illuminated 115 dBm and 104 dBm weak 2 LED s illuminated 103 dBm and 94 dBm medium 3 LED s illuminated 93 dBm and 83 dBm strong GPS Illuminates when the GPS option is fitted and has been successfully configured by the unit It will then flash when the GPS module is rec...

Страница 8: ...to fit the wireless antenna supplied with the unit A range of alternative antennas are available for purchase separately GSM 3G ANT AUX This SMA connector is used to fit the wireless antenna supplied with the unit A range of alternative antennas are available for purchase separately LAN The socket labelled LAN is used to connect the unit to a 10 100Base T LAN using the 2 metre STP Shielded Twisted...

Страница 9: ...movable User Identity Modules R UIM s commonly referred to as SIMs on GSM networks If your service provider does not support R UIMS your router will be provisioned for use on your chosen network when you receive it and this stage of the installation procedure will not be required If your router has not been provisioned you will need to contact your service provider to obtain an IMSI and NAI in ord...

Страница 10: ... RJ45 socket labelled LAN 0 Plug the other end into the LAN socket on your PC or notebook Step 4 Connecting the serial cable For connection to a serial terminal device connect the 25 way D plug on the serial cable provided to the SERIAL connector on the rear of the unit Connect the other end of the cable 9 way D socket to the terminal If the serial connector on the terminal is not a 9 way D plug y...

Страница 11: ...the unit s Ethernet port and DHCP server in order to set up the unit for Internet access See the Sar OS Reference Guide for full details Manual Provisioning If your router was not supplied pre provisioned then you will need to obtain the following details from your Service Provider a 15 digit IMSI International Mobile Subscriber Identity an NAI Network Access Identifier an NAI password When you ha...

Страница 12: ... temp range 20 to 50 degree Celsius Wireless Interface CDMA 1xEV DOrA IS 856 A A Block USB ports Two USB 2 0 Full speed Host OHCI 12 Mbits per second maximum throughput Ethernet interface 10 100Base T auto sensing auto MDI MDX RJ45 Serial interface Sync Async RS232 compatible via 25 way D socket GPS optional Fastrax iTrax03 02 12 channel 153 dBm tracking sensitivity ...

Страница 13: ...t s Models CR4110 Part numbers 81 CR4110 SSEU 00 conform s to the relevant harmonised standards EN60950 1 A11 2004 Health Safety EN301489 25 V2 3 2 2005 07 EMC EN301526 V1 1 1 2006 7 RF spectrum efficiency following the provisions of Council Directive 1999 5 EC on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity Name D Ellison Position Direct...

Отзывы: