Safety Notices 

1)  Please read all instructions before installing and powering the unit. You should keep 

these instructions in a safe place for future reference. 

2)  The CR4110 uses a 12V DC/1.5A power supply (mains adapter). If the mains adapter 

shows signs of damage or malfunction, you should stop using it immediately, turn off 
the  power  at  the  mains  and  disconnect  it  from  the  mains  supply  before  contacting 
your supplier for a repair or replacement. 

3)  Changes  or  modifications  not  expressly  approved  by  the  party  responsible  for 

compliance  could  void  the  user‟s  authority  to  operate  the  equipment.  Use  only  the 
accessories,  attachments,  and  power  supplies  provided  by  the  manufacturer 

– 

connecting  non-approved  antennas  or  power  supplies  may  damage  the  unit,  cause 
interference or create an electric shock hazard, and will void your warranty. 

4)  Do not attempt to repair the product. The unit contains no electronic components that 

can be serviced or replaced by the user. Any attempt to service or repair the unit by 
the user will void the product warranty. 

5)  The CR4110 is  designed for indoor use only  and should  be used in an  environment 

that is suitable for computers and other electronic equipment. 

6)  Ports  that  are  capable  of  connecting  to  other  apparatus  are  defined  as  SELV  ports. 

To  ensure  conformity  with  IEC60950  ensure  that  these  ports  are  only  connected  to 
ports of the same type on other apparatus. 

Note on Wireless Networks 

The  CR4110  is  designed  to  operate  on  CDMA  EV-DO  450  Rev.  A  (Block  A)  networks. 
Throughout this guide these networks will be 

referred to simply as „wireless‟ networks. 

Содержание CR4110

Страница 1: ...C C R R 4 4 1 1 1 1 0 0 4000 Series Router Wireless CDMA EV DO 450 Rev A Installation Guide ...

Страница 2: ...Electrical and Electronic Equipment 2002 96 EC directive has been introduced to ensure that electrical electronic products are recycled using the best available recovery techniques to minimise the impact on the environment This product contains high quality materials and components which can be recycled At the end of its life this product MUST NOT be mixed with other commercial waste for disposal ...

Страница 3: ...r connecting non approved antennas or power supplies may damage the unit cause interference or create an electric shock hazard and will void your warranty 4 Do not attempt to repair the product The unit contains no electronic components that can be serviced or replaced by the user Any attempt to service or repair the unit by the user will void the product warranty 5 The CR4110 is designed for indo...

Страница 4: ...otential danger contact the physician or the manufacturer of the device to verify that the equipment is properly shielded Pacemaker patients are advised to keep the wireless router away from the pacemaker while it is on Wireless routers must NOT be operated on aircraft The operation of wireless appliances in an aircraft is forbidden to prevent interference with communications systems Failure to ob...

Страница 5: ...11 CDMA 1xEV DO 450 Release A wireless capability The CR4110 may be purchased with an optional GPS Global Positioning System module Note You will not be able to use the router for remote communication until you have subscribed to a suitable wireless network service Package Contents When you receive the router carefully unpack it and check the contents These should include CR4110 router system unit...

Страница 6: ... many standard LAN and Internet protocols such as PPP the CR4110 provides a combination of powerful but easy to use configuration management and diagnostic tools This makes it a simple and cost effective solution for migrating existing terminal or telemetry equipment which use wired networks PSTN ISDN etc to wireless operation 1 1 Front Panel Features The front panel of the unit incorporates the U...

Страница 7: ...tors labelled SIGNAL illuminate to indicate the GSM signal strength as follows None illuminated 116 dBm effectively no signal 1 LED illuminated 115 dBm and 104 dBm weak 2 LED s illuminated 103 dBm and 94 dBm medium 3 LED s illuminated 93 dBm and 83 dBm strong GPS Illuminates when the GPS option is fitted and has been successfully configured by the unit It will then flash when the GPS module is rec...

Страница 8: ...to fit the wireless antenna supplied with the unit A range of alternative antennas are available for purchase separately GSM 3G ANT AUX This SMA connector is used to fit the wireless antenna supplied with the unit A range of alternative antennas are available for purchase separately LAN The socket labelled LAN is used to connect the unit to a 10 100Base T LAN using the 2 metre STP Shielded Twisted...

Страница 9: ...movable User Identity Modules R UIM s commonly referred to as SIMs on GSM networks If your service provider does not support R UIMS your router will be provisioned for use on your chosen network when you receive it and this stage of the installation procedure will not be required If your router has not been provisioned you will need to contact your service provider to obtain an IMSI and NAI in ord...

Страница 10: ... RJ45 socket labelled LAN 0 Plug the other end into the LAN socket on your PC or notebook Step 4 Connecting the serial cable For connection to a serial terminal device connect the 25 way D plug on the serial cable provided to the SERIAL connector on the rear of the unit Connect the other end of the cable 9 way D socket to the terminal If the serial connector on the terminal is not a 9 way D plug y...

Страница 11: ...the unit s Ethernet port and DHCP server in order to set up the unit for Internet access See the Sar OS Reference Guide for full details Manual Provisioning If your router was not supplied pre provisioned then you will need to obtain the following details from your Service Provider a 15 digit IMSI International Mobile Subscriber Identity an NAI Network Access Identifier an NAI password When you ha...

Страница 12: ... temp range 20 to 50 degree Celsius Wireless Interface CDMA 1xEV DOrA IS 856 A A Block USB ports Two USB 2 0 Full speed Host OHCI 12 Mbits per second maximum throughput Ethernet interface 10 100Base T auto sensing auto MDI MDX RJ45 Serial interface Sync Async RS232 compatible via 25 way D socket GPS optional Fastrax iTrax03 02 12 channel 153 dBm tracking sensitivity ...

Страница 13: ...t s Models CR4110 Part numbers 81 CR4110 SSEU 00 conform s to the relevant harmonised standards EN60950 1 A11 2004 Health Safety EN301489 25 V2 3 2 2005 07 EMC EN301526 V1 1 1 2006 7 RF spectrum efficiency following the provisions of Council Directive 1999 5 EC on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity Name D Ellison Position Direct...