Digi ConnectTank Getting Started Guide
Page 37
Appendix B:
Digi ConnectTank Attribute
Names
These are the channel names available and shown in Device Cloud for Digi ConnectTank.
Long Name
Short name
Comments/Semantics
distance
val
Sensor tank level in inches.
temperature
tmp
Temperature in degree centigrade.
rssi
rsi
Signal strength.
latitude
lat
LAT.YYY is represented as the geographic
latitude coordinate. For example, 12.9833.
longitude
lon
LON.YYY is represented as the geographic
latitude coordinate. For example, 77.5833.
altitude
alt
ALT.YYY is represented in meters above sea
level. For example, 920 m.
GPS fix type
fix
0 - no fix
1 - valid fix
2 – invalid fix
GPS interval
gin
Interval for GPS information. The range is
1-96.
battery level
bat
The charge remaining in the battery, reported
in percentage.
apn
apn
apn.idigi.com
sensor type
sty
1=M300/150
2=M300/95
tank type
tty
Reserved for future use. Initialize to 0.
The tank type channel has application-defined
values, but is intended for user application.
It is not typically needed in the initial
deployment.
Read period
rdp
Value in minutes. 15 means read every 15
minutes.
Send interval
sdp
Upload interval
a) If the user wants to read the tank reading
every 1 hour and report to Device Cloud in 24
hours:
rdp = 60 (in minutes)
sdp = 24 (in minutes)
b) If the user wants to read the tank reading
every 1/2 hour and report to Device Cloud in
13 hours:
rdp = 30 (in minutes)
sdp = 26 (in minutes)