background image

 

 

Installing the Pole Light 

BEETLE /iSCAN EASY Non Cash 

 

 

17 

You can mount the display in a lower position only if the scanner 9800i is installed. 
 

 

 
If you choose the lower position, remove the plate below (remove two screws – see arrows) and 

mount it in the upper position. 

 

 

 

 
Set the display into place and fix it with the two screws removed before. 

 

 

Lower Position 

Original Position 

Upper Position 

Содержание BEETLE /iSCAN EASY Non Cash

Страница 1: ...BEETLE iSCAN EASY Non Cash Installation manual May 2019 01750249243E...

Страница 2: ...rved Any violations give rise to a claim for damages All rights reserved particularly in relation to the grant of a patent or the registration of a utility model Subject to availability and technical...

Страница 3: ...t Socket 12 Installing the standard Pole Light 13 Installing the ADA II Pole Light 20 Installing the Security Scale 22 Ambient conditions 22 Requirements 22 Installing 23 Connecting the System 25 Star...

Страница 4: ...Certificates 44 CE Marking 44 CSA 44 FCC Class A Declaration 44 30BRecycling the BEETLE iSCAN EASY 44...

Страница 5: ...LE iSCAN EASY is borne by the customer A detailed list of customer responsibilities is given in this manual Installation as well as connection of BEETLE iSCAN EASY may only be executed by technically...

Страница 6: ...gagement For detailed warranty arrangements please consult your contract documents ESD Electrostatic Sensitive Devices Electrostatic sensitive devices ESD may be marked with this sticker When you hand...

Страница 7: ...n such a way that they cannot be stepped on or tripped over Only touch green marked handles and knobs for moving parts Exchange damaged cables immediately In order to completely disconnect the device...

Страница 8: ...ttery is replaced with an equivalent type Otherwise there is danger of explosion Lithium batteries may only be replaced with identical types or other types recommended by the manufacturer Batteries mu...

Страница 9: ...and health are adhered to Provision and installation of auxiliary power or other equipment as required Provision of storage or service as required Provision of a level floor to locate the BEETLE iSCA...

Страница 10: ...Customer Requierements BEETLE iSCAN EASY Non Cash 6 Components...

Страница 11: ...s identical to the information on the delivery ticket Should you notice any transport damages or discrepancies between package contents and delivery ticket or functional defects please inform your con...

Страница 12: ...in the Store Caution Always wear safety gloves and safety shoes with steel toe caps while transporting heavy appliances USA Safety shoes with class 1 toe cap according ASTM F 2412 and ANSI Z41 1 in it...

Страница 13: ...Installing the Pole Light BEETLE iSCAN EASY Non Cash 9 Remove the two screws near the front see arrows Remove two screws see arrows and remove the back cover upwards...

Страница 14: ...eed this part for the floor mounting Caution Close and lock the door Tilt the device max 15 very carefully at the edge of the pallet and set it up at the designated site Ensure that the installation s...

Страница 15: ...alling the Pole Light BEETLE iSCAN EASY Non Cash 11 The following drill template has to be used to fix the BEETLE iSCAN EASY on the floor Drill Template BEETLE iSCAN EASY with Socket All dimensions in...

Страница 16: ...EASY Non Cash 12 Drill Template BEETLE iSCAN EASY without Socket All dimensions in mm Set the back cover in the snap hooks at the BEETLE iSCAN EASY housing see arrows Set the back cover into place and...

Страница 17: ...standard Pole Light Unwrap the pole light and deposit it in a save place The installation might be easier when you uninstall the visual protection before Tilt the display upwards to the position as s...

Страница 18: ...Installing the Pole Light BEETLE iSCAN EASY Non Cash 14 Lift the speaker box upwards and remove it forwards see arrows Unplug the speaker cable Remove the two screws fixing it at the holder...

Страница 19: ...EETLE iSCAN EASY Non Cash 15 Remove the display upwards and place it beside the printer Remove four screws see arrows from the holder Remove see arrow the back side from the front side of the pole lig...

Страница 20: ...ight BEETLE iSCAN EASY Non Cash 16 Push the two tins holder as shown in the picture to the front side of the pole light Mount the front cover to the holder and secure it with the four screws removed b...

Страница 21: ...r position only if the scanner 9800i is installed If you choose the lower position remove the plate below remove two screws see arrows and mount it in the upper position Set the display into place and...

Страница 22: ...Installing the Pole Light BEETLE iSCAN EASY Non Cash 18 Lay the cables inside the pole light in the position as shown in the foolowing pictures and fix them with the tin plates see black arrows...

Страница 23: ...ETLE iSCAN EASY Non Cash 19 Place the rear profile with the right side as viewed from the back of the ACO into the groove of the fixed profile Using both hands squeeze the two profile pieces together...

Страница 24: ...ng the ADA II Pole Light Set the front side of the pole light side with the drillings into place and fix it with a screw Tx20 at both sides from the display Fix the pole light additional with the two...

Страница 25: ...AN EASY Non Cash 21 Fix the holders at first with a screw at the housing of the self checkout 1 Fix the holders also at the pole light 2 Plug the cable fits just in one position and set the back cover...

Страница 26: ...ct influence of an air conditioning system or in a drafty location This is easy to test using a lighter If these conditions cannot be avoided parameters can be adjusted here as well No advertising ban...

Страница 27: ...the security scale which fix it at the palett Remove the security scale from the palett and positione it close to the BEETLE iSCAN EASY Caution Always wear safety gloves and safety shoes with steel to...

Страница 28: ...scale secure it and put it into the security scale housing The screws to fix the security scale are already installed in the right position in the BEETLE iSCAN EASY Loosen the screws for the security...

Страница 29: ...iSCAN EASY 100 V 120 V 200 V 240 V 2 0 A 1 0 A 50 Hz 60 Hz Caution Check that the rating of the appliance corresponds to the local mains voltage Power Connection and LAN Support The BEETLE iSCAN EASY...

Страница 30: ...Connecting the System BEETLE iSCAN EASY Non Cash 26 Mount the cover with two screws Unlock and open the front door of the BEETLE iSCAN EASY...

Страница 31: ...stalled in the power distributor Start the system by switching the switch to position 1 see arrow Disconnecting the System from the Mains Shut down the system by the software application Disconnect th...

Страница 32: ...ich are not covered by warranty Approved Cleaning Materials The items listed below can be ordered from Diebold Nixdorf branch office or your Diebold Nixdorf sales partner Product Name Order Number Exp...

Страница 33: ...Appendix BEETLE iSCAN EASY Non Cash 29 Dimensions No Security Scale...

Страница 34: ...Appendix BEETLE iSCAN EASY Non Cash 30...

Страница 35: ...Appendix BEETLE iSCAN EASY Non Cash 31 One Bag Security Scale...

Страница 36: ...Appendix BEETLE iSCAN EASY Non Cash 32...

Страница 37: ...Appendix BEETLE iSCAN EASY Non Cash 33 Two Bags Security Scale lenghtwise...

Страница 38: ...Appendix BEETLE iSCAN EASY Non Cash 34...

Страница 39: ...Appendix BEETLE iSCAN EASY Non Cash 35 Two Bags Security Scale across...

Страница 40: ...Appendix BEETLE iSCAN EASY Non Cash 36...

Страница 41: ...Appendix BEETLE iSCAN EASY Non Cash 37 Four Bags Security Scale...

Страница 42: ...Appendix BEETLE iSCAN EASY Non Cash 38...

Страница 43: ...Appendix BEETLE iSCAN EASY Non Cash 39 Block Diagram BEETLE iSCAN EASY NON CASH BEETLE M III...

Страница 44: ...Appendix BEETLE iSCAN EASY Non Cash 40 BEETLE iSCAN EASY NON CASH BEETLE M II plus...

Страница 45: ...print scanner optional NFC terminals optional Alternative Payments Coupons vouchers optional Deposit receipts optional Magnetic swipe card reader optional Scanning Printing Functionalities Integration...

Страница 46: ...with ADA II Security Security scale Maximum Ioad 1bag scale 30kg 2 grams resolution 2bag scale 60kg 2 grams resolution DIY scale 180kg S grams resolution Flexible bag holder concept Specific DIY scal...

Страница 47: ...re 70 kPa 106 kPa Installation environments with long periods of sunshine should be avoided Storage Conditions EN 60721 3 1 Class 1k2 Climate test according to IEC 68 EN60068 Ambient temperature 5 C 4...

Страница 48: ...ital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This...

Страница 49: ...materials and components which are recyclable For recycling purposes do not attach any additional adhesive labels to the device Diebold Nixdorf disposes of old devices in a environmentally responsible...

Страница 50: ...Diebold Nixdorf D 33094 Paderborn Order No 01750249243E...