MXS-9100 Optical Switch Rackmount 

 

(Hardware Revision B) Operation Manual 

 
 
 
 
 
 
 
 
 
 
 

 

 

Содержание MXS-9100

Страница 1: ...MXS 9100 Optical Switch Rackmount Hardware Revision B Operation Manual ...

Страница 2: ...e a credit memo for any defective product as an alternative to product replacement or repair DiCon will not accept Buyer generated debit memos Buyer may not set off or withhold payment because any product is defective In no event shall DiCon s liability under this warranty and this contract exceed the purchase price of the products In no event shall DiCon be liable under this warranty or this cont...

Страница 3: ...l Express UPS or DHL International returns may be processed using DiCon s brokerage EWI Inc 305 Harbor Way South San Francisco CA 94080 Contact Harvey Louis at TEL 650 794 1388 FAX 650 794 1389 If one of these carriers or DiCon s broker is not used DiCon may invoice Buyer for any additional costs including duty and taxes Reverse Engineering Confidentiality Buyer shall not reverse engineer decompil...

Страница 4: ...NSIONS 2U 9 MECHANICAL DIMENSIONS 4U 10 PANEL LABELING 1U 11 PANEL LABELING 2U 12 PANEL LABELING 4U 13 ITEMS INCLUDED IN SHIPPING BOX 14 3 Remote Operation 15 OVERVIEW 15 ETHERNET SETUP 15 Getting Started 15 Installing the DeviceManager Program 15 Assigning an IP Address using the DeviceManager 15 Communicating With The MXS 9100 16 COMMAND CONVENTIONS 17 Command Interface Notes 17 SCPI COMMANDS 18...

Страница 5: ... provided by the equipment may be impaired All wiring and installation must be in accordance with local building and electrical codes acceptable to the authorities in the countries where the equipment is installed and used Use only the certified power cord that is suitable rated for the country where the unit is sold Use this unit indoors only Operation of any electrical instrument around flammabl...

Страница 6: ...sts in manufacturing Electrical Specifications Parameter Specification Supply Voltage AC 100 240V 50 60Hz Switch Latching Type Non latching Control Type Ethernet Interface and SCPI Command Set Ethernet Interface Control via the Perle IOLAN DS1 Device Server RJ45 receptacle on the rear panel Front Panel Power Status LED LED will be lit up when power is turned on Equipment Ratings Parameter Specific...

Страница 7: ...Matrix Switch Size 2x8 to 16x16 24x24 to 32x32 48x48 to 96x96 Chassis Size 1U 2U 4U Singlemode 1xN MXS 9100 Chassis Size Number of Switches 1x4 1x8 FC APC FC UPC LC APC LC UPC SC APC SC UPC FC APC FC UPC LC APC LC UPC SC APC SC UPC 1 1U 1U 1U 1U 1U 1U 2 1U 1U 1U 1U 1U 1U 4 1U 1U 1U 1U 1U 1U 6 1U 1U 1U 2U 1U 2U 8 2U 1U 1U 4U 1U 2U Multimode 1xN MXS 9100 Chassis Size Number of Switches 1x4 1x8 1x12 ...

Страница 8: ...MXS 9100 Optical Switch Rackmount Operation Manual 91592 Rev A2 June 21 2019 8 Mechanical Dimensions 1U For illustrative purposes an MXS 9100 MEMS 16x16 Matrix Switch is shown Unit mm ...

Страница 9: ...MXS 9100 Optical Switch Rackmount Operation Manual 91592 Rev A2 June 21 2019 9 Mechanical Dimensions 2U For illustrative purposes an MXS 9100 MEMS 32x32 Matrix Switch is shown Unit mm ...

Страница 10: ...MXS 9100 Optical Switch Rackmount Operation Manual 91592 Rev A2 June 21 2019 10 Mechanical Dimensions 4U For illustrative purposes an MXS 9100 MEMS 96x96 Matrix Switch is shown Unit mm ...

Страница 11: ...2 June 21 2019 11 Panel Labeling 1U Front Panel Labeling For illustrative purposes labeling shown for MXS 9100 MEMS 16x16 Matrix Switch Rear Panel Labeling Screw Heads INPUT Connectors OUTPUT Connectors Mounting Brackets For installation in a rack Power Status LED ...

Страница 12: ...illustrative purposes labeling shown for MXS 9100 MEMS 32x32 Matrix Switch Rear Panel Labeling INPUT Connectors OUTPUT Connectors Mounting Brackets For installation in a rack Power Status LED CE Mark Ethernet RJ45 Connector Rocker Switch Toggle to turn unit on and off Power Cord Inlet Connect power cord 2A Replaceable Fuse ...

Страница 13: ...illustrative purposes labeling shown for MXS 9100 MEMS 96x96 Matrix Switch Rear Panel Labeling INPUT Connectors OUTPUT Connectors Mounting Brackets For installation in a rack Power Status LED CE Mark Ethernet RJ45 Connector Rocker Switch Toggle to turn unit on and off Power Cord Inlet Connect power cord 2A Replaceable Fuse ...

Страница 14: ... each for use in the following o North America DiCon P N 50302 000 or equivalent o Europe DiCon P N 5040095 001 or equivalent o UK DiCon P N 5040096 001 or equivalent o Japan DiCon P N 50303 001 or equivalent o China DiCon P N 50304 001 or equivalent Software CD Includes Manual in PDF form Device Server Installation Software DiCon P N 97064 001 Printed test report ...

Страница 15: ...peration Getting Started 1 Connect an Ethernet cable from the network to the RJ45 port on the rear panel 2 Turn on the unit using the rocker switch on the real panel Installing the DeviceManager Program 3 Insert the Perle IOLAN DS1 Device Server Software CD into your CD ROM drive If the CD does not launch automatically browse the CD and start the installation program device_manager IOLAN_DeviceMan...

Страница 16: ... at the factory and should not be changed The DeviceManager program should normally be used only to find and set the IP address of the MXS 9100 Changing the serial configuration may cause communication problems Communicating With The MXS 9100 After the IP address has been assigned you can open a TCP IP connection with the MXS 9100 over the network To start sending and receiving commands initialize...

Страница 17: ...terminated with a Carriage Return character ASCII 13 Commands may be combined with other commands using a semicolon character Example ROUT6 SCAN 2 ROUT7 SCAN 3 ROUT6 SCAN NEXT ROUT7 SCAN NEXT For SCPI commands the module will remember the portion of a command up to and including the last colon character Subsequent commands may optionally omit that portion of the command to achieve a shorter comman...

Страница 18: ...en output n ROUTe 1 SCAN PREV This command decrements the output channel number to which the specified input channel is connected ROUTe i SCAN SYNChronous Always returns ON SNUMber Returns the module serial number STATus Returns the module status string according to the IQS 9100 manual page 87 This will almost always be READY SYSTem ERRor Error query SYSTem VERSion SCPI version query CLS Clear Sta...

Страница 19: ...pen or closed It will return 0 if closed and 1 if opened ROUTE6 OPEN STAT Queries whether input channel 6 is open or closed It will return 0 if closed and 1 if opened ROUT8 OPEN STATE Queries whether input channel 8 is open or closed It will return 0 if closed and 1 if opened ROUTe i PATH CATalog This command returns the dimensions of input channel i in the format 1xN where N is the number of outp...

Страница 20: ... list of all the output channels currently connected to each input channel Example ROUT SCAN ALL Queries all output channels for each input If an input is not connected to an output a 0 will be returned for that given input 8x8 example with only input channel 2 connected to output 3 0 3 0 0 0 0 0 0 ROUTe i SCAN NEXT This command sets input channel i to the next sequential output channel If the inp...

Страница 21: ...el 0 this command will generate a device error Examples ROUT3 SCAN PREV If input channel 3 is connected to output channel 2 this command connects input channel 3 to output channel 1 ROUTE2 SCAN PREV If input channel 2 is connected to output channel 1 this command connects input channel 2 to output channel 0 parked ROUT1 SCAN PREV If input channel 1 is connected to output channel 9 this command con...

Страница 22: ...ONFIGURED The module is not configured Examples STAT Both examples query the status of the switch module STATUS SYSTem ERRor Error query This command returns the error from the front of the module s error queue and removes that error from the queue The error is reported as two values The first value is the numeric code of the error The second value is a short string description of the error If the...

Страница 23: ...n Bit Decimal OPC Operation Complete 0 1 RQC Request Control N A always 0 1 2 QYE Query Error 2 4 DDE Device Dependent Error 3 8 EXE Execution Error 4 16 CME Command Error 5 32 URQ User Request 6 64 PON Power On 7 128 ESE Query Standard Event Status Enable This query returns the contents of the Standard Event Status Enable Register The events are defined in the table above Enabled event bits are s...

Страница 24: ...CL 0 sets the all input channels to output channel 0 parked no optical continuity RCL 0 is equivalent to RST RST Reset This command sets the all input channels to output channel 0 parked no optical continuity The RST command is equivalent to RCL 0 SAV register Save current state The SAV command saves the current state of the module into memory register number register User configurable memory regi...

Страница 25: ...dule to wait until all pending operations are complete before executing the next remote command System Commands QCT This query returns the cumulative total number of times that the switch states have been recorded for the auto save state feature WEN n Write Channel State Enable This command will either enable n 1 or disable n 0 the auto save state feature With this command enabled the matrix switc...

Страница 26: ...10 nm WL 1 Sets the wavelength calibration to 1550 nm WL n Command is for matrix switches larger than 16x16 Queries Wavelength Calibration Value Queries the value of n used in the wavelength set command Will return the wavelength in units of nm with two decimal points Examples WL 0 1310 00 nm WL 1 1550 00 nm WL Command is for matrix switches larger than 16x16 Queries Set Wavelength Calibration Que...

Страница 27: ... Register Event flags that have occurred This register is set by the module SRE Service Request Enable Register Status Byte flags that trigger RQS This registers is user set STB Status Byte Register Status flags that have occurred This register is set by the module Each bit in these registers is a flag that represents a condition or event In pseudo code the following rules apply 1 IF ESE ESR THEN ...

Страница 28: ...tical cable near a strain relief boot is one of the easiest ways to permanently damage the optical fiber Avoid bending the optical cable over a sharp edge Avoid using cable tie wraps to hold optical cable Tie wraps when tightened can create micro bends or break an optical cable Microbends can cause a dramatic reduction in optical performance Do not pull on the bare fiber as this can break the fibe...

Страница 29: ...nstructions when mating optical connectors Clean both connectors prior to mating Any small particles trapped during the mating process can permanently damage the connector Smoothly insert the appropriate connector ferrule into the adapter Do not allow the fiber tip to contact any surface If the tip accidentally contacts a surface before mating stop Re clean the connector and try again Tighten the ...

Страница 30: ...DiCon Fiberoptics Inc 1689 Regatta Boulevard Richmond CA 94804 USA Phone 510 620 5200 Fax 510 620 4100 Email info diconfiberoptics com Web www diconfiberoptics com ...