MXS-9100 Optical Switch Rackmount Operation Manual
91592 Rev. A2
June 21, 2019
22
STATus?
This command returns the module status string according to table below.
Table 1. Module Status Description
Status Value
Description
UNINITIALIZED
The module is not initialized.
INITINPROGRESS
The module initialization is in progress.
READY
The module is ready.
BUSY
The module is busy.
DISCONNECTED
The module is disconnected.
DEFECTIVE
The module is defective.
UNCONFIGURED
The module is not configured.
Examples:
STAT?
Both examples query the status of the switch module.
STATUS?
SYSTem:ERRor?
Error query. This command returns the error from the front of the module’s error queue and removes
that error from the queue.
The error is reported as two values. The first value is the numeric code of the error. The second value
is a short string description of the error.
If the error queue is empty, it returns error 0, indicating no error.
The maximum error queue size is 8. When the error queue is full, the module will not record new
errors until there is space available in the error queue.
SYSTem:VERSion?
SCPI version query