![Dickinson Antarctic Diesel Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/dickinson/antarctic-diesel/antarctic-diesel_owners-manual_2495005031.webp)
-28-
DO NOT OPERATE THIS PRODUCT UNATTENDED
Lighting Instructions
1. Remove top lid / open door
2. Turn the oil metering valve ON and allow about 30 ml (2 tbls) of fuel into the burner.
3. Turn the oil metering valve OFF
4. Open oven damper if applicable
5. Light the fuel with a twisted paper tissue
6. Replace lid / close door
7. Turn the fan assist to low speed
NOTE: If the flame should go out at this stage, do NOT relight for 10 minutes.
8. The fuel will vaporize in 5 to 10 minutes and when the flames go down in the burner
and start to go out: Turn the valve ON to a low setting that will keep the flames
burning above the burner ring.
9. When the flue pipe is hot(15 minutes of burning) the assist fan may be turned OFF or
on a very low setting.
10. Stay on low setting for 30 minutes before selecting higher settings
INCREASE FUEL SETTINGS IN VERY SMALL INCREMENTS
CAUTION: NEVER LIGHT A FLOODED BURNER
www.dickinsonmarine.com/video.html