Warnings and Disclosures
- Follow all installation and operating procedures.
- The oil heater requires an installed flue for correct operation.
Do not attempt to operate the heater without the flue chimney installed
correctly as required in this manual.
- A permanently open fresh air inlet vent must be installed near the heater to
provide air to the heater for combustion.
- The fuel supply must have a manual shut-off at the fuel tank as well as a
manual shut-off near the heater.
- The fuel must be filtered to at least 10 microns and not exceed 4 PSI of
pressure.
- The fuel type stamped on the side of the oil metering valve is the same as
the fuel in the tank. D-diesel, SO- stove oil or #1 diesel , K-kerosene
- A barometric damper installed and adjusted is a must for good draft and
complete combustion.
- Do not use substitute valves, burners, or fan motors
- Keep the flames burning completely above the top burner ring after heater
is warmed up.
- Turn off the heater when refueling.
- DO NOT OPERATE THIS HEATER UNATTENDED !