OPERATOR'S MANUAL
TROUBLESHOOTING/ 61
Dj SEED MANAGER® SE PLANTER MONITOR
BENCHMARK Series®
11001-1218-200112 Rev A
MONITOR DEAD
Probable Cause
1. Blown console fuse
2. Poor battery connections
3. Cut or broken battery cable
4. Low battery voltage
5. Defective Console
Corrective Action
1. Check console fuse. If blown, replace with a seven one-half (7.5) Amp, type
AGC fuse. If it blows again, contact DICKEY-john Technical Support to replace
console. See inside, back cover of this manual for phone number.
2. Clean and tighten battery connections
3. Repair by splicing, soldering, and individually heatshrinking each
wire. Use only Rosin Core Solder.
4. Verify battery voltage is at least twelve (12) volts. If not, recharge or replace
battery.
5. Contact DICKEY-john Technical Support. See inside, back cover of this manual
for phone number.
BATTERY SYMBOL APPEARS ON DISPLAY
Probable Cause
1. Low battery voltage
2. Intermittent harness short to ground
3. Poor battery connections
Corrective Action
1. Recharge or replace battery
2. Locate short and repair by splicing, soldering, and sealing the wire
3. Clean and tighten battery connections
TROUBLESHOOTING
Содержание Seed Manager SE
Страница 20: ...18 INSTALLATION OPERATOR S MANUAL Dj SEED MANAGER SE PLANTER MONITOR BENCHMARK Series 11001 1218 200112 Rev A...
Страница 40: ...38 SETUP OPERATOR S MANUAL Dj SEED MANAGER SE PLANTER MONITOR BENCHMARK Series 11001 1218 200112 Rev A...
Страница 50: ...48 OPERATE OPERATOR S MANUAL Dj SEED MANAGER SE PLANTER MONITOR BENCHMARK Series 11001 1218 200112 Rev A...
Страница 60: ...58 ALARM OPERATOR S MANUAL Dj SEED MANAGER SE PLANTER MONITOR BENCHMARK Series 11001 1218 200112 Rev A...
Страница 62: ...60 ERRORCODES OPERATOR S MANUAL Dj SEED MANAGER SE PLANTER MONITOR BENCHMARK Series 11001 1218 200112 Rev A...