56/ ALARM
OPERATOR'S MANUAL
Dj SEED MANAGER® SE PLANTER MONITOR
BENCHMARK Series®
11001-1218-200112 Rev A
11. Pressure Lo Limit Warning
This occurs when any pressure input
falls below the value entered for
Pressure Lo Limit in the SETUP
MODE. The alarm beeps for three (3)
seconds and the pressure sensor
number and actual pressure, in oz/in
2
(kPa), are displayed. If multiple
pressure sensors fall below the limit, the
pressure sensor numbers are displayed
sequentially, along with their respective
pressures. Figure 63 shows a Pressure
Lo Limit Warning on pressure sensor
two (2) with a pressure of 2.7 oz/in
2
.
12. Hopper Lo Warning
This occurs when any hopper input
signals a low material level. The alarm
sounds continuously and the hopper
sensor number is displayed along with
the HOPPER and LO messages. If
multiple hopper sensors signal a low
material level, the hopper sensor
numbers are displayed sequentially.
Figure 64 shows a Hopper Lo Warning
on hopper two (2).
Figure 63
PRESSURE LO LIMIT Warning Display
Figure 64
HOPPER LO Warning Display
HOPPER
LO
Содержание Seed Manager SE
Страница 20: ...18 INSTALLATION OPERATOR S MANUAL Dj SEED MANAGER SE PLANTER MONITOR BENCHMARK Series 11001 1218 200112 Rev A...
Страница 40: ...38 SETUP OPERATOR S MANUAL Dj SEED MANAGER SE PLANTER MONITOR BENCHMARK Series 11001 1218 200112 Rev A...
Страница 50: ...48 OPERATE OPERATOR S MANUAL Dj SEED MANAGER SE PLANTER MONITOR BENCHMARK Series 11001 1218 200112 Rev A...
Страница 60: ...58 ALARM OPERATOR S MANUAL Dj SEED MANAGER SE PLANTER MONITOR BENCHMARK Series 11001 1218 200112 Rev A...
Страница 62: ...60 ERRORCODES OPERATOR S MANUAL Dj SEED MANAGER SE PLANTER MONITOR BENCHMARK Series 11001 1218 200112 Rev A...