OPERATOR’S MANUAL
Control Point
®
11001-1489-201702 Rev B
KEYBOARD PROGRAMMING / 57
PROGRAMMING LIQUID APPLICATION RATES
(F4)
The Application Rate screens list four liquid materials. Each material screen
contains a set of values for product application rate, APR steps, min/max
limits, and blast rate. The pre-programmed values for these parameters are
usually the same for all liquid pre-wet materials and the same for all liquid
anti-icing materials. Each screen should be edited and modified as
required.
Note:
F5 should be used to select between liquids, pre-wet and
anti-ice before proceeding.
1. From the keyboard, press F4 to obtain the Liquid Application Rates
screen, refer to (
). Four (4) liquid product names are shown,
each followed by the word ENABLED or DISABLED.
2. Select a material using the corresponding number key.
3. Edit the parameters on the selected screen. Check each following item
for desired settings.
NOTE: The Material Selection screen
has been updated to limit the
display of prewet and anti-ice
materials to only the active type
when the Boom 5 input is
configured for prewet/anti-ice
selection. For example, if
materials 1 and 2 are prewet
and 3 and 4 are anti-ice with
the Boom 5 switch in the prewet
mode, only materials 1 and 2
will appear. Changing the
switch to anti-ice at the operate
screen, only materials 3 and 4
will display.
–
ENABLE
- When enabled, the material appears on the Material/
Manual Speed Select screen in the Operate mode to allow
selecting for use. Enter Y for YES (enabled), N for No (disabled).
At least one liquid product must be enabled. If the controller is
granular only, all liquids can be disabled. All products can be
programmed (and calibrated) now and enabled later.
–
STEP METHD
- Y (Yes) selects the Step Method or N (No) the Rate
method to specify application rates (APRs). The parameters for
each method are different and all items below change with the
selection (Refer to Figure 33 for Rate Method screen).
Changing from one APR Method to the other for any material
automatically clears all previous rates from that method.
The STEP Method permits the APR to be changed by a fixed
increment using the “+/–” switch on the Switch Module. The Rate
method allows programming of up to ten (10) different APRs - Rate
1 through Rate 10. If less than ten rates are chosen, enter a zero
(0) for each rate following the last one programmed. The initial rate
displayed in the Operate mode is Rate 1. Other rates are selected
by pressing the “+/–” switch on the Switch Module.
–
APP START
(Step Method) – Defines the start-point APR.
–
IC/DC STP
(Step Method) - Sets the increase/decrease step value.
–
MIN APP
(Step Method) – Defines the minimum APR limit for the
product.
Содержание Control Point
Страница 1: ...CONTROL POINT CONTROL SYSTEM Operator s Manual SINCE 1966 ...
Страница 5: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B IV ...
Страница 7: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 2 SAFETY NOTICES ...
Страница 13: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 8 INTRODUCTION ...
Страница 29: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 24 START UP AND FAMILIARIZATION ...
Страница 77: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 72 KEYBOARD PROGRAMMING ...
Страница 79: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 74 SYSTEM CALIBRATION ...
Страница 91: ...OPERATOR S MANUAL Control Point 11001 1489 201702 Rev B 86 SYSTEM CALIBRATION ...