4.3.6. Control/faults
When you push on the ‘A- button’ -> you can see / check the different working hours of the burner & engine.
When the engine is working and there’s a detection, the fan will operate (while the engine is turning).
The fan will still work -60 seconds (cooling process in the machine) at deactivation of the engine (no
fuel/or at switching off diesel engine: feedback low oil pressure). At a fault message (temperature too high) ->
fan continues to run until the temperature has been dropped to +-80°C (non-adjustable value).
When the key contact has been turned off in case of overheating or the emergency stop has been pushed,
the next steps will happen at switching on the machine again:
- The fuel engine/diesel engine will be switched off after 3 seconds (because temperature is still high).
- The fan starts to operate (until the machine temperature drops below 80°C) so the engine can be restarted
again.
The faults like indicated on the next page can appear (fault will be present during 3 sec.).
A fault can be canceled by turning the burner switch to position ‘0’. If the error is still present, the message
will appear again and the machine returns to malfunction (eliminate the cause).
A message will appear on the control display or the burner switch lamp remain illuminated constantly (push
on the ‘ESC’ button to remove the message) when service is necessary.
Possible disturbances - flash frequence burner switch (between the flash frequence is a pause time provided):
1x Alternator does not charge
2x Flame protection - no flame
3x Flame protection - after burn
4x No flow available (flow switch fault)
5x No pressure present (pressure switch fault)
6x Temperature inside the machine too high
7x Oil pressure too low diesel engine
(only @ diesel version)
4.4. Spraying tools
The high pressure spray gun has been carried out with a (grey) handle.
No spraying: release the lever in the handle.
Spraying: pressing the lever in the handle.
Spray security: unlock the block- system from the lever.
The machine is standard provided with one or two spray lances.
Mount (tighten) also the spray lance to the spray gun via the coupling. At use of reel(s): always unroll the reel
hose(s) completely during spraying activities to ensure an optimal performance!
Check during praying regularly or the lance coupling still sits firmly on the spray gun.
Block system