1 9
4. CONNECTIONS
• Any installation work or maintenance to the
supply system (gas, electricity, water) must only
be carried out by the utility company or an
authorised installation technician.
•
Refer to the appliance dataplate for the product code.
•
See the installation diagram for the type and position of
appliance connections.
4.1.
ELECTRIC APPLIANCES
4.1.1. ELECTRICAL CONNECTION
(Fig. 4A-Table C).
IMPORTANT!
Before connecting, make sure the mains voltage
and frequency match that given on the dataplate.
•
To access the terminal board, remove the control panel of
the appliance by removing the fixing screws (fig. 2A 1-2).
•
Connect the power cable to the terminal board as shown in the
wiring diagram attached to the appliance.
•
Secure the power cable with the cable gland.
IMPORTANT!
The manufacturer declines any liability if the
safety regulations are not respected.
4.1.2. POWER CABLE
Unless otherwise specified, our appliances are not equipped
with a power cable. The installer must use a flexible cable having
characteristics at least equivalent to H05RN-F rubber-insulated
type cables. Protect the cable section outside the appliance with
a metal or rigid plastic pipe.
4.1.3. CIRCUIT BREAKER
Install a circuit breaker ahead of the appliance. Contact
opening distance and maximum leakage current must
comply with current regulations.
4.2.
EQUIPOTENTIAL NODE AND EARTH
CONNECTION
Connect the appliance to an earth; it must be included in an
equipotential node by means of the screw located at the
front right under the frame. The screw is marked with the
symbol
.
3.1. COMBINING APPLIANCES
•
(Fig.1A) Undo the 4 fixing screws and remove the control
panels of the appliances.
•
(Fig.1B) Remove the fixing screw nearest the control
panel, from each side to be joined.
•
(Fig.1D) Bring the appliances together and level them by
turning the feet until the tops match.
•
(Fig.1C) Turn one of the two plates inside the appliances
180º.
•
(Fig.1E) From inside the control panel of the same
appliance, join them at the front side, screwing one TE
M5x40 screw (supplied) on the opposite insert.
3.2. FLOOR FIXING
To avoid accidental tipping of built-in half-module appliances
installed separately, fix them to the floor carefully following the
instructions enclosed with the corresponding accessory
(F206136).
3.3 INSTALLATION ON BRIDGE, CANTILEVER
FRAME OR CEMENT PLINTH
Carefully follow the instructions enclosed with the
corresponding accessory.
Follow the instructions supplied with the optional product
chosen.
3.4 SEALING GAPS BETWEEN
APPLIANCES
Follow the instructions supplied with the optional sealing
paste pack.