2 4
3. FAULT CODE TABLE
Code = no. lamp
short signals
Fault
Actions
no signal
no fault, normal operation
none
1
coil without current, overcurrent in hardware if the fault signal remains after repeated
switching on: call customer service
2
current too high in coil, overcurrent in
software
if the fault signal remains after repeated
switching on: call customer service
3
cooling sheet inverter temperature too high allow the appliance to cool, clean the fan
filter and switch on again
4
cooking zone temperature too high,
cooking zone sensor disconnected
allow the appliance to cool, turn the power
knob to "0" and switch on again; if the fault
signal remains after repeated switching on:
call customer service
5
breakage of power knob cable
call customer service
6
temperature inside appliance too high
allow the appliance to cool, lower the room
temperature
7
cooking zone sensor short circuit
the appliance continues to work normally,
but the cooking zone temperature is no
longer controlled; call customer service
10
communication error: no connection
between card and generator
Call Customer Service