32
4 Dialogic® DSI SS7MD Board Configuration and Operation
4.5
Protocol Configuration
The Development Package contains the
s7_mgt
protocol configuration utility that performs initialization of all
the software modules running on the signaling board. It reads the protocol configuration data from a text
file, called
config.txt
, and provides a quick and flexible method of configuring the protocol modules without the
need to write any software for that purpose. Refer to
Section 4.5.1, “Protocol Configuration Using the
s7_mgt Utility” on page 32
for more information.
Alternatively, the protocol stack may be configured by sending the individual configuration messages
documented in the per-module Programmer’s Manuals for each protocol module. This approach is of
particular use when the application needs to reset the board and run a new configuration without stopping
the application program. Refer to
Appendix A, “Protocol Configuration Using Discrete Messages”
for more
information.
4.5.1
Protocol Configuration Using the s7_mgt Utility
The
s7_mgt
protocol configuration utility uses the
config.txt
protocol configuration file by default. However, the
-k
option allows the user to specify an alternative filename if required. For example:
s7_mgt -kmyconfig.txt
The format of each configuration command is described in
Chapter 7, “Configuration Command Reference”
.
The
s7_mgt
protocol configuration utility can optionally be configured to send a message to a nominated
module on completion of the configuration sequence. This option is activated using the
-i
option to specify the
receiving module_id. For example:
s7_mgt –i0xef
To assist problem diagnosis, the
s7_mgt
utility can be run using the
-d
option that generates additional
diagnostic output. For example:
s7_mgt –i0xef -d
The following is an example
config.txt
protocol configuration file:
********************************************************************************
*Example Protocol Configuration File (config.txt) for use with
* Dialogic(R) DSI SS7MD Network Interface Boards.
********************************************************************************
* Configure individual boards:
* For SS7MD boards:
* SS7_BOARD <board_id> <board_type> <flags> <code_file> <run_mode>
SS7_BOARD 0 SS7MD 0x0002 ss7.dc6 LSL
*
* Configure individual E1/T1 interfaces:
*LIU_CONFIG <board_id> <liu_id> <liu_type> <line_code> <frame_format> <crc_mode>
* [<build_out>]
LIU_CONFIG 0 0 5 1 1 1 0
*
* MTP parameters:
* MTP_CONFIG <reserved> <reserved> <options>
MTP_CONFIG 0 0 0x00040000
*
* Define linksets:
* MTP_LINKSET <linkset_id> <adjacent_spc> <num_links> <flags> <local_spc> <ssf>
MTP_LINKSET 0 1 1 0x0000 2 0x08
*
* Define signaling links:
* MTP_LINK <link_id><linkset_id><link_ref><slc><board_id><stream><blink>
* <timeslot><flags> [<data_rate>]
*
MTP_LINK 0 0 0 0 0 0 0 1 0x0006
*
* Define a route for each remote signaling point:
* MTP_ROUTE <dpc> <norm_ls> <user_part_mask> <flags> [<second_ls>]
MTP_ROUTE 0 0 0xffff
*
*
* Define any user provided Layer 4 protocol:
* MTP_USER_PART <service_ind> <module_id>