105
Dialogic
®
DSI SS7MD Programmer’s Manual Issue 3
6.7.4
API_MSG_CNF_IND – Configuration Completion Status Indication
Synopsis
Message issued by the
s7_mgt
protocol configuration utility on completion of initial configuration sequence.
Format
Description
This message is issued by the
s7_mgt
protocol configuration utility on completion of the initial configuration
sequence and indicates either success (status=0) or an error condition that occurred during configuration.
The message is only issued when
s7_mgt
is run with the –
i
command line option specifying the module ID of
the
Notification Module
to which the message should be sent. For example:
s7_mgt –i0x2d
Note:
It is recommended that the user invoke this option, then wait for an API_MSG_CNF_IND
message to ensure that the application does not attempt to send messages until initial
configuration is complete.
Parameters
The API_MSG_CNF_IND message header uses the following parameter:
•
completion_status
The result of initial configuration. The following table shows the possible values and their meanings.
MESSAGE HEADER
Field Name
Meaning
type
API_MSG_CNF_IND (0x0f09)
id
0
src
0xcf
dst
Notification module (see below)
rsp_req
0
hclass
0
status
completion_status (see below)
err_info
Reserved for future use.
len
0
Value
Meaning
0
Success
1
Error opening the config.txt protocol configuration file
2
Syntax or value error in the config.txt protocol configuration file
3
Error during configuration (invalid parameters)
4
Error during configuration (no response)