7 Configuration Command Reference
7.6
TUP Configuration Commands
The TUP configuration commands are:
•
TUP_CONFIG
-
Configure TUP
•
TUP_CFG_CCTGRP
-
Configure a TUP Circuit Group
7.6.1
TUP_CONFIG – Configure TUP
Synopsis
The global configuration parameters for the TUP module.
Syntax
TUP_CONFIG <res1> <res2> <user_id> <options> <num_grps> <num_ccts> <partner_id>
Example
TUP_CONFIG 0 0 0x2d 0x8541 4 128
Parameters
The TUP_CONFIG command includes the following parameters:
•
<res1>
,
<res2>
Reserved for backwards compatibility. These fields should be set to 0.
•
<user_id>
The module_id of the application running on the host that uses the TUP module.
•
<options>
A 16-bit value containing global run-time options for the operation of the TUP module. The meaning of
each bit is as defined for the
options
parameter in the
TUP Configure Request
message as detailed in
the
TUP Programmer's Manual
.
•
<num_grps>
The maximum number of TUP circuit groups that the user intends to use. This must not exceed the
maximum number of circuit groups supported; otherwise module configuration fails. Typically, this
parameter should be set to the maximum number of circuit groups supported.
•
<num_ccts>
The maximum number of TUP circuits that the user intends to use. This must not exceed the maximum
number of circuits supported; otherwise module configuration fails. Typically, this parameter is set to:
— 32 times the number of groups for E1 operation
— 24 times the number of circuit groups for T1/J1 operation.
Note:
The valid range for the circuit identifier (cid) is from 0 to one less than the maximum number of
circuits (
<num_ccts>
).
•
<partner_id>
Optional parameter for use when operating in dual resilient configuration. This parameter is the
module_id of the
partner
TUP module (equivalent to the
ucic_id
field in the
TUP Configure Request
message as documented in the
TUP Programmer’s Manual
).