30
4 Dialogic® DSI SS7MD Board Configuration and Operation
NUM_MSGS 1000
* Number of standard size messages
*
* Optional Modules that run on the host:
*
* LOCAL 0x23
* ISUP module
* LOCAL 0x4a
* TUP module
* LOCAL 0x33
* SCCP module
* LOCAL 0x14
* TCAP module
* LOCAL 0x22
* MTP3 module
*
*
* Redirection of status indications:
*
REDIRECT 0xdf 0x2d * LIU/MTP2 status messages -> upe
REDIRECT 0xef 0x2d * Other indications -> upe
*
* Start-up all local tasks:
*
FORK_PROCESS ./ssdm
FORK_PROCESS ./tim_lnx
FORK_PROCESS ./tick_lnx
FORK_PROCESS ./s7_mgt
FORK_PROCESS ./upe
*
********************************************************************************
4.4.2
Generating the system.txt Configuration File
This section describes the procedure for generating a
system.txt
configuration file and details any operating
system specific differences in behavior among the development packages.
First, the file must contain LOCAL declarations for all modules that are to run on the host computer. At a
minimum, this must include the
ssdm
module and the timer module. Hence, the following declarations must
exist:
LOCAL
0x20
* ssdm - Board interface task
LOCAL
0x00
* tim_xxx - Timer task
LOCAL declarations are also required for any optional modules running on the host. Typically, this includes
the
s7_mgt
protocol configuration utility and the user's own application module. It may also include any host-
based protocol modules and the
s7_log
utility. For example:
LOCAL
0xcf
* s7_mgt - Management/config task
LOCAL
0x2d
* upe - Example user part task
LOCAL
0x3d
* s7_log - Prints messages to screen/file
LOCAL
0x22
* MTP3 module
Once all the LOCAL declarations are in place, REDIRECT commands should be added for all modules that are
logically running on the board so that any messages destined for these modules are transported via the
ssdm
module (module_id = 0x20).
The following REDIRECT commands are always required:
REDIRECT
0x71 0x20 * MTP2 module_id
REDIRECT
0x10 0x20 * LIU module
REDIRECT
0x8e 0x20 * onboard management module
If ATM support is required, then the following REDIRECT commands are also required:
REDIRECT
0x31 0x20 * ATM Module
REDIRECT
0x41 0x20 * Q.SAAL Module
Having ensured that all modules running on the board are accessible, it is then necessary to ensure that any
status indications issued from the board successfully arrive at a module running on the host. If this does not
happen, the system quickly runs out of available messages for inter-process communication.
Two module_ids (0xdf and 0xef) require redirection to a suitable process running on the host; initially these
messages should be redirected to the
s7_log
utility that prints out a line for each message received.
Ultimately, the user's own application should deal with these notifications.
REDIRECT
0xdf 0x3d* LIU/MTP2 status messages -> s7_log
REDIRECT
0xef 0x3d* Other indications -> s7_log
Содержание DSI SS7MD
Страница 1: ...www dialogic com Dialogic DSI SS7MD Network Interface Boards Programmer s Manual...
Страница 8: ...8 1 Introduction...
Страница 42: ...42 4 Dialogic DSI SS7MD Board Configuration and Operation...
Страница 46: ...46 5 Program Execution...