Power Supply Terminal Connection 

 

Located at the bottom right hand side of the enclosure is the terminal block required for 
connecting the Positive, Negative and Earth Ground to the power supply. 
 
WARNING: Floating Neutrals are not permissible within the wiring of the system and the 
installer must verify the connections. This will “Void” all warranties. 
WARNING: Ground connection is required to provide safety and proper operation of the 
system. 
WARNING: There can be no more than 305Vac measured from Live to Earth ground on 
TB1 
 

NOTE:

 The load and voltage loss of the cable must be quantified before selecting the 

cable size requirements.  
 

 

DC TERMINAL BLOCK 

 

RS485 Communication Connection  

 
The connection of the RS485 cable is vitally important to the operation of the system. 
This connection provides all the events and alarms to the Master controller that is being 
used with the installation. 
 
Factory connected wiring color code: 
 

The RS485 consists of 3 conductors 

Boards are Labeled                        Description   

                 Color Code  

Label “A” 

Communications “A” 

Gray or White 

Common 

Common for RS485 

Yellow 

Label “B” 

Communications “B” 

Blue 

 
 
 

Содержание SafeSite D564B13001

Страница 1: ...fixture ratings DO NOT mount near gas or electric heaters Equipment should be mounted in locations and at heights where it will not be subjected to tampering by unauthorized personnel The use of acces...

Страница 2: ...less than the ignition temperature of the Hazardous Atmosphere Do not operate in ambient temperatures above those indicated on the Products label Do not operate if the fasteners are not properly tigh...

Страница 3: ...ISQUE D EXPLOSION LA SUBSTITUTIOND E COMPOSANTSP EUTR ENDRE CE MATERIEL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE I DIVISION 1 Warning DO NOT mount near gas or electric heaters Equipment should be...

Страница 4: ...ument No 9100 127 2044 99 Rev C Release Date August 2020 Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel 732 919 3119 Fax 732 751 5778 Web www dialight com Page 4 of 21 System Overvi...

Страница 5: ...ll VOID all warranties and could cause premature failures 1 Mains connection using a 3 conductor Power Cable 14AWG minimum to 10AWG maximum 2 An RS485 communications cable This is required to be a 3 c...

Страница 6: ...ute 34 South Farmingdale NJ 07727 Tel 732 919 3119 Fax 732 751 5778 Web www dialight com Page 6 of 21 Maximum cable diameter is 47 inches NOTE Liquid tight Conduit and TECK armored cable are acceptabl...

Страница 7: ...ed and tapped for all wiring connections WARNING No additional holes can be added to the enclosure NOTE Multiple grounding points are provided in the enclosure for protective and functional Earth Grou...

Страница 8: ...eb www dialight com Page 8 of 21 SIDE VIEW OF THE POWER SUPPLY ENCLOSURE Installation and Wiring WARNING Before any service or wiring is conducted ensure the DC at the breaker is off SYSTEM BLOCK DIAG...

Страница 9: ...NG Ground connection is required to provide safety and proper operation of the system WARNING There can be no more than 305Vac measured from Live to Earth ground on TB1 NOTE The load and voltage loss...

Страница 10: ...ble with RS 485 communication cable as purchased from Dialight part number CAB 183BFD Where represents the cable length in feet Option 2 When 2 Conductors a drain wire and either a shield or braid is...

Страница 11: ...Translator must be set to a unique address for each Power Supply connected to the Controller NOTE If ordered as a system typically SW1 will be factory set per this table i e JB4 xxxxxxxxxx would have...

Страница 12: ...ction between the Flash Head and the Power Supply requires an 8 conductor cable NOTE This is the only connection to the Flash Head that is required WARNING If the cable is not color coded or numbered...

Страница 13: ...ead and Power supply have the same protection board Two conductors are required for the Red Beacon and six for the White Strobe Red L864 Connections Terminal block J2 pins 1 and 2 White L865 Connectio...

Страница 14: ...ash head and Power supply have the same protection board Two conductors are required for the Red Beacon and two for the White Strobe Red L864 Connections Terminal block J2 pins 1 and 2 White L865 Conn...

Страница 15: ...d to the tower Scrape away access paint powder coating as necessary 5 Minimize loop areas by tying all cables against the tower or passing through conduit 6 Ensure the Power Supply enclosure is electr...

Страница 16: ...are factory set to the off position and positions 2 3 4 should be checked that they are set in the off position Micro Filter Assembly Image Capacitor Voltage Indication Safety Warning This unit holds...

Страница 17: ...Driver Diagnostic LED LED 1 Indicates more than 50V is present on the output and gives a good indication that the Beacon Driver module is working Microcontroller Board Diagnostic LED s LED 1 Red on th...

Страница 18: ...e incoming RS485 cable ports B Pin1 and A Pin3 can be seen The Common connection point is the center pin 2 Translator Indicators Translator Communications LED s Once communication has begun LED s labe...

Страница 19: ...nt No 9100 127 2044 99 Rev C Release Date August 2020 Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel 732 919 3119 Fax 732 751 5778 Web www dialight com Page 19 of 21 Translator Indi...

Страница 20: ...ev C Release Date August 2020 Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel 732 919 3119 Fax 732 751 5778 Web www dialight com Page 20 of 21 Mechanical Dimensions of Power Supply E...

Страница 21: ...Route 34 South Farmingdale NJ 07727 Tel 732 919 3119 Fax 732 751 5778 Web www dialight com Page 21 of 21 Replacement Part Numbers Exploded view REV ECO No DRN CKD APP QA CM DATE A 14911 SA DW JLM JP J...

Отзывы: