4
THE FIRST STEPS
Once you have selected your CS 50 Sensor or the Emulator
and created a new job, you will move to the Image view.
This view allows you to Auto Calibrate the CS 50,
and to manually adjust the CS 50‘s Exposure, Gain, and
Focus, and also to set the Lighting Mode (On, Off , or Strobe).
Note: If you load a job from your PC or upload a job from the
CS 50, you will automatically move to the Edit view.
You can return to the Connect view and click the Modify
button to adjust additional CS 50 settings, such as TCP/IP
settings, Industrial Protocol settings, RS-232 settings,
Ethernet settings, and CS 50 Software button settings.
You can also rename your CS 50 (alphanumeric characters
only - [0-9], [a-z], and [A-Z]). Click the Apply button when
you have adjusted the CS 50‘s settings as needed.
After you have created a new job, loaded a job from your PC,
or uploaded a job from the CS 50, you will proceed to the Edit
view to refi ne your machine vision job.
The Camera parameters allow you to set Gain, Exposure,
Focus, Trigger, and Lighting.
Inspection Outputs options and di-soric Link functionality
allow you to connect your job to the outside world.
This is also the view where you can add multiple tools to the
job. The tool icons are located above the main view area.
When a tool is selected, it appears in the job list area
to the left of the main view.
Adjust CS 50 Sensor Settings
Edit the Job