Replacing the Battery
Replacing the Fuses
Warning:
TO AVOID ELECTRIC SHOCK, DISCONNECT THE TEST
LEADS FROM ANY SOURCE OF VOLTAGE BEFORE
REMOVING THE FUSE DOOR.
1. Disconnect the test leads from the meter and any
item under test.
2. Open the fuse door by loosening the screw on the
door using a Phillips head screwdriver.
3. Remove the old fuse from its holder by gently
pulling it out.
4. Install the new fuse into the holder.
5. Always use a fuse of the proper size and value
(0.5A/250V fast blow for the 400mA range,
10A/250V fast blow for the 10A range).
6. Put the fuse door back in place. Insert the screw and
tighten it securely.
Warning:
TO AVOID ELECTRIC SHOCK, DO NOT OPERATE YOUR
METER UNTIL THE FUSE DOOR IS IN PLACE AND
FASTENED SECURELY.