18
10.
If the surface charge is detected, the tester will
automatically discharge the battery for 5
seconds and wait for 15 secods before
proceeding to the test.
11.
The tester automatically starts the S.L.D.R battery test.
12.
The tester will automatically
determine if the battery needs to be
charged for a real load test. If the
charge is needed. The user will see
the tester initiate charge.
The user may stop charging and go back to main nenu by pressing
“STOP”
13.
The user may see necessary info,
including remaining time counting
down on the screen.
NOTE: Charging status of SS
(Soft-Start) / CC mode / CV mode /
END, will be displayed on the bottom of the screen.
OCP (Over current protection) / OTP (over tempeture protection) will be
displayed on the lower right of the screen if occurred.
14.
Once the charging is done. The tester will
automatically perform a real load test.
15.
The tester will display the test result on the
screen. The user may press the directional keys
to review between 2 pages of the result.
The test result will also be saved and uploaded to the cloud.
INITIATE CHARGE
■■■□□□□□
XX.XX V XX.X A
CHARGED AH: XX.X AH
TEMP: XX
°
C / XX
℉
REMAINING TIME: 25:00
TEST RESULT
GOOD & PASS
F/W: V00.A H/W: V00.A
WARRANTY CODE
ASDJHGTYHV6J8KGDR46U
TEST RESULT
GOOD & PASS
OCV: XX.XX V SOC: XXX%
CCA: XXXX SOH: XXX%
RATED: XXXX
C.T: MIN: XX.X AH