REGISTER AN ACCOUNT ON MY BATTERY EXPERT (CLOUD): 

1. 

Switch on a laptop and go to

www.mybatteryexpert.com

 

2. 

Select “Register” on the lower right corner. 

3. 

Enter Email address, company ID, & Shop ID and c

lick “Submit” 

 

Содержание BT2300-PLUS

Страница 1: ...1 Model BT2300 PLUS Cloud Ready Battery Service Station Owner s manual Read entire manual before using this product ...

Страница 2: ...N Capture Via External Scanner Field upgrade 6 Power Supply for ECU reflash 7 12V Lead Acid EFB AGM VRLA LFP battery charge 8 Precise Temperature Compensation 9 12 24 Volt Starting Charging System Diagnostic 10 Print out test results 4 COLOR DISPLAY STATUS INDICATOR 2 THERMINAL PRINTER USB Type A ALPHANUMERIC KEYPAD VOLTMETER AMP CLAMP JACK OPTIONAL 10 FEET DETACHABLE HEAVY DUTY CABLE SET WITH TEM...

Страница 3: ...turer and manufacturer of any equipment you intend to use in the vicinity of the battery Observe cautionary markings on these items 3 Do not expose the tester to rain or snow PERSONAL SAFETY PRECAUTIONS 1 Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery 2 Have plenty of fresh water and soap nearby in case battery acid contacts ...

Страница 4: ...rd having an equipment grounding conductor and a grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances DANGER Never alter AC cord or plug provided if it will not fit outlet have proper outlet installed by a qualified electrician Improper connection can result in a risk of an electric shock USE OF AN ADAPTER ...

Страница 5: ...ilable The temporary adapter should be used only until a properly grounded outlet can be installed by a qualified electrician DANGER Before using adapter as illustrated be certain that center screw of outlet plate is grounded The green colored rigid ear or lug extending from adapter must be connected to a properly grounded outlet make certain it is grounded If necessary replace original outlet cov...

Страница 6: ... of the connectors NOTE ALWAYS HOLD THE CONNECTORS INSTEAD OF THE WIRES WHEN INSERTING OR REPLACING THE CLAMP SET REPLACE THE CLAMP SET 1 Hold the connectors and pull them off from the back off the tester 2 Insert a new clamp set by following above install the clamp set instruction NOTE ALWAYS HOLD THE CONNECTORS INSTEAD OF THE WIRES WHEN INSERTING OR REPLACING THE CLAMP SET ...

Страница 7: ...verfill 5 If it is necessary to remove battery from vehicle to test always remove ground terminal from battery first Make sure all accessories in the vehicle are off to ensure you do not cause any arcing OPERATION USE Note Each time you connect the tester to a battery the tester will run a quick cable verification to ensure a proper connection through the output cables to sensors in the clamp jaws...

Страница 8: ...REGISTER AN ACCOUNT ON MY BATTERY EXPERT CLOUD 1 Switch on a laptop and go to www mybatteryexpert com 2 Select Register on the lower right corner 3 Enter Email address company ID Shop ID and click Submit ...

Страница 9: ... mailbox for the verification mail and click on the URL link to complete the verification 5 Use the default password 000000 to login My Battery Expert Cloud and you will see a notification of successful registration ...

Страница 10: ...10 6 My Battery Expert will request the user to set up a new password for the first login Simply enter a new password and click Submit to proceed to the dashboard of My Battery Expert ...

Страница 11: ... Access to the dash board of My Battery Expert 8 Click Device management and then click Add device to generate a 1D 2D barcode or a Registration code for the tester that you want to upload the test results ...

Страница 12: ... pop up options You may select 1D 2D barcode and scan the code with the external barcode scanner on the tester Or you can simply select manually enter the registration code 2D Barcode QR code Manually Input the code 1D Barcode code39 ...

Страница 13: ...Select the WiFi you want to connect And enter the WiFi password 7 Once the WiFi is successfully connected You will see WiFi connected is displayed on the screen with the name of the WiFi 8 Go to upper level of setting page by pressing left directional button And select REGISTRATION 9 Choose either SCAN CODE or MANUALLY INPUT SETTING 5 DEALER INFORMATION 6 TIME ZONE 7 TEST COUNTER WIFI WIFI POWER O...

Страница 14: ... uploaded to MY BATTERY EXPERT However test results with and without VIN RO numbers will be saved in the tester and able to be transferred to the PC S W for further review ENTER THE DEALER INFO 1 Select Setting from the main menu 2 Select DEALER INFORMATION 3 Enter the Dealer Code Hold the button to switch from number to alphabet Press Stop to delete the input at the cursor position if needed Use ...

Страница 15: ...Now the test results will be uploaded with dealer code PAPER REPLACEMENT 1 Open the clear cover 2 Place a new paper roll in the compartment Make sure the thermal side is upside placed as below 3 Pull a short length of paper from the compartment and press down the clear cover to close DEALER ADDRESS OPTIONS CLEAR ALL ...

Страница 16: ...ll pop up warnings to remind the user to revise The user may ignore the incorrect VIN or RO and proceed to the test However if the user ignores the VIN or RO the test result WILL NO be uploaded to the cloud The test result will only be saved in the tester which can only be reviewed by the PC S W 4 Select PDI Charge or Auto Test Charge PDI Charge stands for Pre delivery Insepection If charging is n...

Страница 17: ...rating Select the rating according to the battery that is being tested 7 Set capacity use the keypad to unput the capacity or use directional kep to adjust the capacity 8 Press Enter to start testing The test will perform the S L D R test and then automatically determine if the battery needs to be charged for a real load test 9 The tester will pop up a warning if the voltage is unstable The user m...

Страница 18: ... Charging status of SS Soft Start CC mode CV mode END will be displayed on the bottom of the screen OCP Over current protection OTP over tempeture protection will be displayed on the lower right of the screen if occurred 14 Once the charging is done The tester will automatically perform a real load test 15 The tester will display the test result on the screen The user may press the directional key...

Страница 19: ...arged 3 CAUTION The battery may be serviced but decrease the capability of starting the engine gradually The battery may fail under extreme climate conditions There may be a poor connection between the vehicle and the battery affect the charging function Please pay attention to the battery for replacement consideration and charging system checking 4 RECHARGE RETEST Battery is discharged the batter...

Страница 20: ...ry in sleep mode 3 The tester will pop up a warning if the voltage is unstable The user may press STOP to go back to the main menu 4 The tester will start charging the LiF battery 5 The user may see necessary info including charged AH tempeture and estimated remaining time counting down on the screen 6 The tester will automatically stop chatging when the battery is fully charged or charging time r...

Страница 21: ...rm cranking charging tests 2 Enter VIN code manually or use barcode scanner to scan the VIN code from the chassis 3 Enter RO number NOTO If the VIN or RO is not entered correctly the tester will pop up warnings to remind the user to revise The user may ignore the incorrect VIN or RO and proceed to the test However if the user ignores INPUT SUPPLY VOLTAGE INITIATE CHARGE POWER SUPPLY XX XX V XX X A...

Страница 22: ...AL The system is showing normal draw Press ENTER to perform the charging system test CRANKING VOLTS LOW The cranking voltage is below normal limits troubleshoot the starter with manufacturers recommended procedure CRANKING NOLTS NOT DETECTED The cranking voltage is not detected 6 Press ENTER to begin charging system test INVALID RO RESULT NOT SUITABLE FOR WARRANTY IGNORE INVALID VIN RESULT NOT SUI...

Страница 23: ... normal output from the alternator No problem is detected LOW CHARGING VOLTS WHEN TEST AT IDLE The alternator is not providing sufficient current to the battery Check the belts to ensure the alternator is rotating with engine running If the belts are slipping or broken replace the belts and retest Check the connections from the alternator to the battery If the connection is loose or heavily corrod...

Страница 24: ...actual testing measured CHARGING SYSTEM HIGH WHEN TEST WITH ACCESSORY LOADS The voltage output from the alternator to the battery exceeds the normal limits of a functioning regulator Check to ensure there are no loose connections and that the ground connection is normal If there are no connection issues replace the regulator Since most alternators have the regulator built in this will require you ...

Страница 25: ...results Use directional keys to switch between two result pages 13 Select YES to print out the result or select NO to return to main menu AMP CLAMP VOLT PROBE INSTRUCTION GUIDE Select DC AC Current DC Voltage measurement from the main menu DC AC Current measurement 1 Install the 9V battery 2 Connect Clamp Meter to the jack A on BT2300 PLUS 3 Press the button ZERO Make sure the display reads zero 4...

Страница 26: ...t within the network of the battery 3 Read the displayed value NOTE Do not test more than 60V it may damage the tester SETTING 1 LCD BACKLIGHT Select LCD BACKLIGHT and use directional keys to adjust the brightness Press enter to confirm setting and return to the setting menu SETTING 2 LANGUAGE 3 CLOCK 4 CLEAR MEMORY ...

Страница 27: ...ct YES to clear memory Select NO to return to the setting menu 5 DEALER INFORMATION Enter DEALER INFORMATION to edit the dealer code dealer name and dealer address Please refer to BINGDING THE TESTER WITH THE CLOUD ACCOUNT 6 TIME ZONE Enter TIME ZONE and use directional keys to adjust the UTC time zone The tester will automatically re match the date and time from the internet when the WiFi is conn...

Страница 28: ...THE CLOUD ACCOUNT for the WiFi setting procedures 9 OTA UPGRADE If a new fireware is available the tester will receive a notification Only if the WiFi is connected to ask the user to go to OTA UPGRADE and upgrade the F W by following the step by step instrucion SETTING 5 DEALER INFORMATION 7 TEST COUNTER 8 WIFI TIME ZONE SETTING 5 DEALER INFORMATION 6 TIME ZONE 8 WIFI TEST COUNTER 1 BATTERY TEST 3...

Страница 29: ...or the procedures in details PC S W 1 Install the BT2300 PLUS PC S W on your laptop or PC 2 Use the male to male USB cable to connect your laptop to the tester 3 Make sure the tester is switched on 4 Initiate the BT2300 PLUS PC S W 5 Select one of the features from the BT2300 PLUS PC S W main menu BT2300 PLUS PC S W MAIN MENU SETTING 9 OTA UPGRADE B VERSION ...

Страница 30: ... DOWNLOAD TEST RESULT Click DOWNLOAD TEST RESULT icon from the main menu and click START to start transferring all test records from BT2300 PLUS to the USB connected laptop or PC Once completed click BACK on the top right corner in order to go back to the main menu of the PC S W Note The PC S W will pop up a question to check if the user wants to delete the records from BT2300 PLUS ...

Страница 31: ...on DELETE TEST RESULT icon to delete all test records in BT2300 PLUS UPGRADE SOFWARE Click on UPGRADE SOFTWARE icon and select the correct bin file to upgrade BT2300 PLUS WARRANTY CODE Click WARRANTY CODE to decode warranty codes ...

Страница 32: ...ions must be retorqued and the batteries should be cleaned periodically What is an AGM battery An AGM battery is a lead acid electric storage battery that is sealed using special pressure valves and should never be opened is completely maintenance free has all of its electrolyte absorbed in separators consisting of a sponge like mass of matted glass fibers uses a recombination reaction to prevent ...

Страница 33: ...ften be called COMMERCIAL batteries They have to be much more powerful and more robust than batteries intended for cars What is STATE OF HEALTH It means how much battery capacity is left comparing with the marked original battery capacity What is STATE OF CHARGE It means how many percent of the battery is actually charged What is CCA COLD CRANKING AMPS The current in amperes which a new fully char...

Страница 34: ...t be sent pre paid with dated proof of purchase Damage incurred during shipment is the responsibility of the shipper customer returning unit If the returned unit qualifies for warranty the shipper will only incur shipping cost The seller reserves the right to substitute or offer alternative warranty options at its discretion The sole and exclusive remedy for any unit found to be defective is repai...