27
PART 1 - QUICK INSTALLATION GUIDE
PRELIMINARY CHECKS
During the initial installation and maintenance, make
sure that
ends of the line wires are not
live
.
During the initial installation and maintenance, make sure that
the system is not under
pressure
to ACCESS THE DRIVE WIRING
, open the front cover as shown on p. 5
DO NOT OPEN INVERTER COVERS
, except for the connector cover
Models T / T
(three-phase IN / three-phase OUT) do not have the switch on board, for these
models the inverter supply line must be protected in accordance with the regulations
-
Install the inverter in a place:
o
protected from the elements
o
ventilated, free from excessive humidity or excessive dust
o
as close as possible to the pump
o
make sure that does not receive harmful vibrations or mechanical stress from connected
pipelines
-
Control panel:
1- START/STOP button
2- Red LED (power)
3- Green LED (status)
4- Display
5- SET button
6- Confirm button
7-
Scrolling UP / DOWN
/
RIGHT / LEFT
INSTALLATION AND HYDRAULIC CONNECTIONS
OUT
IN
OK
Install in a
vertical
position
NO
Do not
install
in a horizontal
position
O-RING
NO SEALING
NO CANAPA
NO TEFLON
O-RING
Do not
use
sealant in the
three-pieces
joint; are
already
equipped
with O-Ring
The freezing of the
liquid contained in the
inverter body causes
irreversible damage
to the inverter
1
3
4
5
6
7
2