42
-
After performing the operations described in the INSTALLATION chapter, the inverter can be started.
-
When STEADYPRES is switched on, it enters the STARTING phase, which lasts 10 seconds, after
which
STEADYPRES returns to the same operating conditions in which it was when it was last
switched off
:
o
in WORK mode if at the time of the last shutdown was IN SERVICE
o
in OUT OF SERVICE mode if at the time of the last shutdown was OUT OF SERVICE
(OFF)
-
In case of accidental fall of the power line, if it STEADYPRES was in serivce, when the power returns,
it automatically returns in service
-
To put STEADYPRES
IN SERVICE / OUT OF SERVICE,
beat the START / STOP button.
- In applications with parallel inverters (MASTER / SLAVE) is just the MASTER inverter that receives input
from the keyboard
- SLAVE inverters operate independently only if the MASTER is turned off, in which case they receive input
from its own keyboard.
- In each group can be only one MASTER, one SLAVE 1 and one SLAVE 2.
- In normal operation, you can view the status parameters.
For visualization of the operating parameters see
QUICK INSTALLATION GUIDE
LIGHT SIGNALS
keyboard
ON
OFF
BLINKING
POWER
STATUS
STEADYPRES does not detect power supply.
WARNING:
cannot guarantee the absence of power supply, the
electronic board may be faulty, but under tension
POWER
STATUS
STEADYPRES
is live, but the pump is not running (STAND-
BY)
POWER
STATUS
STEADYPRES
is live, and the pump is running
POWER
STATUS
STEADYPRES
is live, but out of serivce; the re-arm is only
manual
POWER
STATUS
STEADYPRES
is in ALARM mode, re-arm is only manual
INSPECTION MENU
the menu INSP (inspection) allows you to view the history of the inverter: the operating hours,
number of starts, alarm recording.
INSP
WH
OPERATING HOURS
Operating hours with the pump running
TH
TOTAL OPERATING HOURS
Total No. Hours working
NS
NO. START-UPS
total Number of start-ups
SH
AVERAGE NO. START-UPS
Average number of start-ups per working hour.
E1
LAST FAULT
last fault that occurred in chronological order
EH
TIME OF LAST FAULT
time at which the fault occurred (referred to TH)
EE
ERROR RESET
to reset the error log press the ENTER key and hold,
until "OK" is confirmed on the display
(ENTER
****
OK)