background image

www.dfi.com

CS331-C246/Q370

Chapter 5

 

- Intel AMT Settings

55

3.   Enter a new password in the space provided under Intel(R) ME New Password then press 

Enter. The password must include: 

•  8-32 characters 

•  Strong 7-bit ASCII characters excluding 

: , 

and

 ”

 characters

•  At least one digit character (0, 1, ...9)

•  At least one 7-bit ASCII non alpha-numeric character, above 0x20, (e.g. !, $, ;)

•  Both lower case and upper case characters

Intel(R) Management Engine BIOS Extension v12.0.0.0010/Intel(R) ME v12.0.40.1433

Copyright(C) 2003-17 Intel Corporation. All Rights Reserved

MAIN MENU

MEBx Login

>  Intel(R) ME General Settings

    Intel(R) AMT                               <Enabled>          

>  Intel(R) AMT Configuration

MEBx Exit

         Intel(R) ME Password

[

↑↓

] =Move Highlight     [Enter] =Select Entry           [Esc] =Exit

Intel(R) ME New Password

4.   You will be asked to verify the new password. Enter the same new password in the space 

provided under Verify Password then press Enter. 

Intel(R) Management Engine BIOS Extension v12.0.0.0010/Intel(R) ME v12.0.40.1433

Copyright(C) 2003-17 Intel Corporation. All Rights Reserved

MAIN MENU

MEBx Login

>  Intel(R) ME General Settings

    Intel(R) AMT                               <Enabled>                  

>  Intel(R) AMT Configuration

MEBx Exit

          Intel(R) ME Password

[

↑↓

] =Move Highlight     [Enter] =Select Entry           [Esc] =Exit

Verify password

5.   Select 

Intel(R) ME General Settings

 then press Enter. 

Intel(R) Management Engine BIOS Extension v12.0.0.0010/Intel(R) ME v12.0.40.1433

Copyright(C) 2003-17 Intel Corporation. All Rights Reserved

MAIN MENU

>  Intel(R) ME General Settings

    

Intel(R) AMT                               <Enabled> 

>  Intel(R) AMT Configuration

MEBx Exit

[

↑↓

] =Move Highlight     [Enter] =Select Entry           [Esc] =Exit

Intel(R) Management Engine BIOS Extension v12.0.0.0010/Intel(R) ME v12.0.40.1433

Copyright(C) 2003-17 Intel Corporation. All Rights Reserved

MAIN MENU

MEBx Login

>  Intel(R) ME General Settings

    Intel(R) AMT                               <Enabled>                                                                            

>  Intel(R) AMT Configuration

MEBx Exit

        Intel(R) ME Password

[

↑↓

] =Move Highlight     [Enter] =Select Entry           [Esc] =Exit

2.   Select 

MEBx Login 

and press Enter. You will be prompted for a password. The default 

password is “

admin

”. Enter the default password in the space provided under Intel(R) ME 

Password then press Enter.

Intel(R) ME Password

Содержание CS331-C246

Страница 1: ...A52410940 CS331 C246 Q370 MicroATX Industrial Motherboard User s Manual...

Страница 2: ...ers FCC and DOC Statement on Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to p...

Страница 3: ...erfaces 21 RJ45 LAN Ports 22 Audio 22 USB Ports 23 I O Connectors 24 SATA Serial ATA Connectors 24 Digital I O Connector 24 Cooling Fan Connectors 25 Power Connectors 25 Chassis Intrusion Connector 26...

Страница 4: ...You must take extra care in han dling them to ensure against electrostatic build up 1 To prevent electrostatic build up leave the system board in its anti static bag until you are ready to install it...

Страница 5: ...300mm 2 x COM ports Serial ATA data cable Length 500mm With LOCK Thermal solution For 35W Height 37 3mm Thermal solution For 65W Height 72 8mm Thermal solution For 95W Height TBD LPC EXT RS232 module...

Страница 6: ...ETHERNET Controller CS331 C246 1 x Intel I211AT PCIe 10 100 1000Mbps 1 x Intel I219LM PCIe 10 100 1000Mbps with iAMT 12 0 only Xeon Core i7 i5 support iAMT CS331 Q370 1 x Intel I211AT PCIe 10 100 1000...

Страница 7: ...ction allows you to use a USB keyboard or USB mouse to wake up a system from the S3 STR Suspend To RAM state RTC Timer The RTC installed on the system board allows your system to automatically power o...

Страница 8: ...It is capable of running at a maximum transmission speed of up to 10 Gbit s 1 2 GB s and is faster than USB 3 1 Gen 1 5 Gbit s or 625 MB s USB 2 0 480 Mbit s or 60 MB s and USB 1 1 12Mb s USB 3 1 red...

Страница 9: ...485 Select 4 8 1 5 System Fan 2 SATA 3 COM 1 RS232 422 485 Select JP1 1 USB 3 1 1 2 Power Select JP15 USB 3 1 3 4 Power Select JP16 1 Mini PCIe mSATA Signal Select JP9 USB 2 0 7 8 Power Select JP17 1...

Страница 10: ...r rate Single Channel DIMMs are on the same channel DIMMs in a channel can be identi cal or completely different However we highly recommend using identical DIMMs Not all slots need to be populated Du...

Страница 11: ...Eject Tab Step 3 Step 2 Step 1 Step 1 Step 2 Step 3 System Memory Installing the DIMM Module CPU The system board is equipped with a surface mount LGA 1151 socket This socket is exclu sively designed...

Страница 12: ...ign with the chamfer corner of the CPU socket shown in the photo Golden triangular mark CPU Installing the CPU Installing the CPU 1 Make sure the PC and all other peripheral devices connected to it ha...

Страница 13: ...cor rect orientation Alignment key Alignment key CPU Installing the CPU 8 Close the load plate then push the load le ver down While closing the load plate make sure the front edge of the load plate s...

Страница 14: ...sink already has a patch of thermal paste on its underside Peel the strip that covers the paste before you place the fan heat sink on top of the CPU 2 Place the heat sink on top of the CPU The 4 spri...

Страница 15: ...maly of the followings is encountered a CMOS data is corrupted b you forgot the supervisor or user password c failure to start the system due to BIOS mis configuration it is suggested that the system...

Страница 16: ...jumpers setting COM 2 COM 1 JP8 COM 2 2 1 9 JP1 COM 1 JP3 COM 1 JP2 COM 1 JP6 COM 2 JP10 COM 2 JP3 COM1 JP10 COM2 COM 1 COM 2 1 2 3 4 5 6 7 8 9 1 3 4 6 On RS232 default 3 5 4 6 On RS422 Full Duplex 3...

Страница 17: ...in functions of COM 1 and COM 2 will vary according to JP4 s and JP7 s setting respectively 1 2 3 4 5 6 7 8 9 2 1 9 Pin RS232 RS232 with power 1 DCD 12V 2 SIN SIN 3 SO SO 4 DTR DTR 5 GND GND 6 DSR DSR...

Страница 18: ...n 5V 2 3 On 5V 1 2 On 5VDU default 3 1 2 3 1 2 USB 3 1 3 4 JP16 1 2 On 5VDU default 2 3 On 5V USB 2 0 9 10 JP18 1 2 On 5VDU default 2 3 On 5V USB 2 0 7 8 JP17 PS 2 Power Select JP20 is designed to sel...

Страница 19: ...N ports 2 USB 3 1 Gen 1 ports 2 USB 3 1 Gen 2 ports 1 Line in jack optional 1 Line out jack 1 Mic in jack PS 2 Keyboard Mouse Port PS 2 Keyboard Mouse This rear I O port is used to connect a PS 2 mous...

Страница 20: ...compatible UARTs that can be used with modems serial printers remote display terminals and other serial devices Connecting External Serial Ports Your COM port may come mounted on a card edge bracket...

Страница 21: ...D monitor This port supports DVI D signal only Con nect the display device s cable connector to the DVI I port After plugging the cable connector into the port gently tighten the cable screws to hold...

Страница 22: ...hole connecting interface for inserting a plug Optional Line in Jack Light Blue This jack is used to connect any audio devices such as Hi fi set CD player tape player AM FM radio tuner synthesizer et...

Страница 23: ...d edge bracket Install the card edge bracket to an available slot at the rear of the system chassis and then insert the USB port cables to a connector BIOS Setting Configure these onboard USB devices...

Страница 24: ...Configure the Serial ATA drives in the Chipset menu PCH IO Configuration SATA And RST Configuration submenu of the BIOS Refer to the chapter 3 for more information Features 2 2 G2 I C Battery SATA 3...

Страница 25: ...the power supply unit are designed to fit the 24 pin and 8 pin connectors in only one orientation Make sure to find the proper orientation before plugging the connectors The system board requires a mi...

Страница 26: ...ront Panel Connector 2 2 G2 I C Battery HDD LED Hard Disk Drive LED Lighting of the LED indicates that the hard drive is being accessed RESET Reset Switch This switch allows you to reboot without havi...

Страница 27: ...F connector Make sure pin 1 of the audio cable is aligned with pin 1 of the S PDIF connector 1 5 5V SPDIF out GND SPDIF in 2 2 G2 I C Battery S PDIF The LAN LED connector is used to detect the connect...

Страница 28: ...s a master by initiating data transfer SMBus Connector SMBus 1 2 5 GND SMB_DATA SMB_CLK 3V3DU SMB_ALERT Standby Power LED This LED will lit red when the system is in the standby mode It indicates that...

Страница 29: ...f the LPC connector LPC Pin Assignment Pin Assignment Pin Assignment 1 L_CLK 2 L_LAD1 3 L_RST 4 L_LAD0 5 L_FRAME 6 3 3V 7 L_LAD3 8 GND 9 L_LAD2 10 11 SERIRQ 12 GND 13 5VSB 14 5V LPC Connector 13 14 1...

Страница 30: ...t Install PCI Express cards such as network cards or other cards that comply to the PCI Express specifications into the PCI Express x4 slot Mini PCIe Socket The full size Mini PCIe socket supports USB...

Страница 31: ...ystem to run After you power up the system the BIOS message appears on the screen and the memory count begins After the memory test the message Press DEL to run setup will appear on the screen If the...

Страница 32: ...07 00 56 50 Advanced Security Boot Main 0x906EA U0 32 KB x 6 32 KB x 6 256 KB x 6 12 MB 6Core s 12Thread s B4 0 7 1 100 4096 MB 2133 MHz C246 12 0 40 1433 Corporate SKU Wed 07 10 2019 System Time The...

Страница 33: ...according to your preference RC ACPI Settings This section is used to configure the system ACPI parameters Enable or disable Sys tem wake on alarm event When enabled System will wake on the hr min se...

Страница 34: ...y Vanderpool Technology Aptio Setup Utility Copyright C 2019 American Megatrends Inc Version 2 20 1271 Copyright C 2019 American Megatrends Inc Advanced Select Screen Select Item Enter Select Change O...

Страница 35: ...chnology Aptio Setup Utility Copyright C 2019 American Megatrends Inc Version 2 20 1271 Copyright C 2019 American Megatrends Inc ME State Manageability Features State AMT BIOS Features AMT Configurati...

Страница 36: ...es F9 Optimized Defaults F10 Save Exit ESC Exit Configure OEM Flags Aptio Setup Utility Copyright C 2019 American Megatrends Inc Version 2 20 1271 Copyright C 2019 American Megatrends Inc ME State Man...

Страница 37: ...ity Copyright C 2019 American Megatrends Inc Version 2 20 1271 Copyright C 2019 American Megatrends Inc ME State Manageability Features State AMT BIOS Features AMT Configuration ME Unconfig on RTC Cle...

Страница 38: ...INT1A interface will not be available NCT6116D Super IO Configuration This section is used to configure the I O functions supported by the onboard Super I O chip WatchDog Timer Unit Selection Aptio Se...

Страница 39: ...pyright C 2019 American Megatrends Inc Version 2 20 1271 Copyright C 2019 American Megatrends Inc Advanced Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F9 Optim...

Страница 40: ...mart Fan 1 Control Boundary 1 Boundary 2 Boundary 3 Boundary 4 Speed Count 1 Speed Count 2 Speed Count 3 Speed Count 4 System Smart Fan 2 Control Boundary 1 Boundary 2 Boundary 3 Boundary 4 Speed Coun...

Страница 41: ...specify how the host computer and the remote computer which the user is using will ex change data Both comput ers should have the same or compatible settings COM1 Console Redirection Console Redirecti...

Страница 42: ...r disable USB Mass Storage Driver Support Advanced CSM Configuration This section is used to configure the CSM settings Enable Disable CSM Support Version 2 20 1271 Copyright C 2019 American Megatrend...

Страница 43: ...em wake up from S3 S4 by USB KB MS 5V No support system wake up from S3 S4 by USB KB MS Aptio Setup Utility Copyright C 2019 American Megatrends Inc Version 2 20 1271 Copyright C 2019 American Megatre...

Страница 44: ...he setup options Ipv4 PXE Support Enable or disable IPv4 PXE boot support If disabled IPv4 PXE boot support will not be avail able Ipv6 PXE Support Enable or disable IPv6 PXE boot support If disabled...

Страница 45: ...imized Defaults F10 Save Exit ESC Exit Enabled Enabled PCI Express Configuration This section configures PCI Express settings Refer to following sections for more information SATA And RST Configuratio...

Страница 46: ...Mini_PCIE M 2 Enable or disable the port Hot Plug Enable or disable the hot plug function of the PCI Express root port PCIe Speed Select the speed of the PCI Express root port Auto Gen1 Gen 2 or Gen3...

Страница 47: ...Intel Optane System Acceleration for CS331 Q370 only This option allows you to create RAID or Intel Rapid Storage configuration with Intel Optane system acceleration on Serial ATA devices Use RST Lega...

Страница 48: ...ral Help F2 Previous Values F9 Optimized Defaults F10 Save Exit ESC Exit System Mode This field displays whether the system is in User or Setup mode Secure Boot Enable or disable Secure Boot Please re...

Страница 49: ...settings to a USB flash device Restore Setting from file This field will appear only when a USB flash device is detected Select this field to restore setting from the USB flash device Boot Graphics R...

Страница 50: ...be updated and will cease to be effective Updating the BIOS To update the BIOS you will need the new BIOS file and a flash utility Please contact techni cal support or your sales representative for t...

Страница 51: ...RAID 1 Use four new drives or an existing drive and three new drives for this configuration RAID Level Min Drives Protection Description RAID 0 2 None Data striping without redundancy RAID 1 2 Single...

Страница 52: ...e the up or down arrow keys to select the RAID level and press Enter 4 Use the up or down arrow keys to scroll through the list of hard drives and press En ter to select the drive 5 Press Enter 6 Use...

Страница 53: ...main menu of the AMI BIOS 2 In the Advanced menu select PCH FW Configuration 3 Select Enabled in the AMT BIOS Features field Configure Management Engine Technology Parameters Aptio Setup Utility Copyr...

Страница 54: ...nc Save Options Save Changes and Reset Discard Changes and Reset Restore Defaults Boot Override Save Setting to file Restore Setting from file Chipset Advanced Main Security Boot Save Exit Select Scre...

Страница 55: ...Intel R ME v12 0 40 1433 Copyright C 2003 17 Intel Corporation All Rights Reserved MAIN MENU MEBx Login Intel R ME General Settings Intel R AMT Enabled Intel R AMT Configuration MEBx Exit Intel R ME P...

Страница 56: ...sword in the space provided under Intel R ME Password then press Enter Intel R Management Engine BIOS Extension v12 0 0 0010 Intel R ME v12 0 40 1433 Copyright C 2003 17 Intel Corporation All Rights R...

Страница 57: ...p And Configuration Power Control Disabled Enabled INTEL R AMT CONFIGURATION Move Highlight Enter Complete Entry Esc Discard Changes 13 In the Intel R AMT Configuration menu select SOL Storage Redirec...

Страница 58: ...ghlight Enter Complete Entry Esc Discard Changes 16 Select KVM Feature Selection then press Enter Select Enabled or Disabled then press Enter Intel R Management Engine BIOS Extension v12 0 0 0010 Inte...

Страница 59: ...choose to use a password only during setup and configuration or to use a pass word anytime the system is being accessed Intel R Management Engine BIOS Extension v12 0 0 0010 Intel R ME v12 0 40 1433 C...

Страница 60: ...NAME SETTINGS Host Name Domain Name Shared Dedicated FQDN Dynamic DNS Update 24 Select Domain Name then press Enter Enter the computer s domain name then press Enter Intel R Management Engine BIOS Ext...

Страница 61: ...433 Copyright C 2003 17 Intel Corporation All Rights Reserved Move Highlight Enter Select Entry Esc Exit TCP IP SETTINGS Wired LAN IPV4 Configuration 27 Select Periodic Update Interval then press Ente...

Страница 62: ...0 0 Preferred DNS Address 0 0 0 0 Alternate DNS Address 0 0 0 0 Enter Complete Entry Esc Discard Changes 32 Select Subnet Mask Address then press Enter Enter address then press Enter Intel R Manageme...

Страница 63: ...t C 2003 17 Intel Corporation All Rights Reserved WIRED LAN IPV4 CONFIGURATION DHCP Mode Disabled IPV4 Address 0 0 0 0 Subnet Mask Address 0 0 0 0 Default Gateway Address 0 0 0 0 Preferred DNS Address...

Страница 64: ...rrent Provisioning Mode Provisioning Record Provisioning Server IPV4 IPV6 _ Provisioning Server FQDN _ RCFG TLS PKI Provisioning Mode PKI 40 In the Intel R Remote Setup And Configuration menu select P...

Страница 65: ...ved INTEL R REMOTE CONFIGURATION Start Configuration Move Highlight Enter Select Entry Esc Exit This will activate Remote Configuration Continue Y N 44 Press Esc until you return to the Intel R Remote...

Страница 66: ...SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 Hash Name Active Default Algorithm VeriSign Class 3 VeriSign Class 3 Go Da...

Страница 67: ...sales representatives or from the website download page at https www dfi com DownloadCenter Auto run Menu After inserting your DVD ROM into your optical drive the System Utility auto run menu may pop...

Страница 68: ...cognized and configured properly in the system 1 Setup is ready to install the utility Click Next 2 Read the license agreement then click Accept 3 Go through the readme docu ment for more installation...

Страница 69: ...screen will turn blank for 1 to 2 minutes while WinSAT is running before the Windows 10 desktop appears The blank screen period is the time Windows is testing the graphics perfor mance We recommend th...

Страница 70: ...Fin ish Restarting the system will al low the new software installa tion to take effect 1 Setup is ready to install the driver Click Next Intel LAN Drivers 1 Setup is ready to install the driver Click...

Страница 71: ...installing status in the progress 4 Click Install to begin the in stallation 6 After completing installation click Finish Intel ME Drivers 1 Setup is ready to install the driver Click Next 2 Read the...

Страница 72: ...hange to choose another destination folder 4 Please wait while the product is being installed 5 After completing installation click Finish Intel Serial IO Drivers 1 Setup is ready to install the drive...

Страница 73: ...iver Click Next 5 Setup is now installing the driver 3 Go through the readme docu ment for system requirements and installation tips then click Next 6 Click Yes I want to restart this computer now the...

Страница 74: ...ported Software 74 Adobe Acrobat Reader 9 3 1 Click Next to install or click Change Destination Folder to select another folder 2 Click Install to begin installa tion 3 Setup is now installing the dri...

Страница 75: ...power management for the storage subsystem 2 Read the license agreement and click I accept the terms in the License Agreement Then click Next 1 Setup is ready to install the utility Click Next 3 Go th...

Страница 76: ...www dfi com CS331 C246 Q370 Chapter 6 Supported Software 76 6 Click Yes I want to restart this computer now to com plete the installation and then click Finish...

Отзывы: