Clearance Requirements
To maintain proper airflow once the processor is installed on the system
board, the processor and fan heatsink require certain space clearances.
The clearance above the processor must be at least 0.3 inches. The
clearance on at least 3 of 4 sides of the processor and fan heatsink
must be at least 0.2 inches. All cables (for floppy drive, hard drive, CD-
ROM, etc.) must be routed clear of the processor and its airspace.
Fan Exhaust
The processor must be kept cool by using a processor with heatsink and
fan attached. The temperature of the air entering the fan/heatsink cannot
exceed 45
o
C (113
o
F). The ambient or room temperature must be below
37
o
C (99
o
F).