background image

DeZURIK

 

G-Series Cylinder Actuator Used on BAW Butterfly Valves

 

August 2012

 

Page 5 

D10480 

 

Actuator Identification

 

(Continued)

 

Table A: Cylinder Identification 

Cylinder 

  “A” 

IN 

MM 

C4 

4.5 

115 

C6 

6.5 

165 

C8 

8.5 

215 

C10 

10.5 

265 

 

Adjusting Position Stops 

The G-Series Cylinder Actuators have both open and closed position stops. See Figure 2 for position 
stop identification. 

 

Figure 2 – Position Stops 

The position stops are factory set and do not require adjustment unless the actuator has been 
disassembled or actuator orientation has been changed. 

Adjusting the Open Position Stop 

On 6A and 12A cylinder actuators, the Open Position Stop is located in the end of the extension cap 
opposite the cylinder. See Figure 2. 

 

The actuator must be mounted before adjusting the position stop.

 

1.  Loosen the Open Position jam nut. 

2.  Adjust the Open Position screw to the proper position. Counterclockwise rotation of screw 

increases the stroke, clockwise rotation of screw decreases the stroke. 

3.  Lock the Open Position screw in place with the jam nut. 

 

Содержание G-SERIES

Страница 1: ...DeZURIK Inc Sartell Minnesota USA Phone 320 259 2000 www dezurik com info dezurik com DEZURIK G SERIES CYLINDER ACTUATOR USED ON BAW BUTTERFLY VALVES Instruction D10480 August 2012 ...

Страница 2: ...ction when dealing with hazardous pipeline materials Handle valves which have been removed from service with the assumption of pipeline material within the valve Inspection Your G Series Cylinder Actuator has been packaged to provide protection during shipment however it can be damaged in transport Carefully inspect the unit for damage upon arrival and file a claim with the carrier if damage is ap...

Страница 3: ...upply 4 Lubrication 4 Actuator Identification 4 Adjusting Position Stops Adjusting the Open Position Stop 5 Adjusting the Closed Position Stop 6 Removing Actuator 6 Installing Actuator 6 Removing Cylinder 8 Installing Cylinder 8 Disassembling Actuator 9 Reassembling Actuator 10 Changing Mounting Positions 12 Troubleshooting 12 ...

Страница 4: ...arings using one of these lubricants Keystone Zeniplex 1 recommended Amoco Amolith Grease 1 EP alternate Amsoil GHD alternate Mobil Mobilux EP 1 alternate Petro Canada Vultrex MPG EP 1 alternate Shell Alvania EP 1 alternate Texaco Multifak EP 1 alternate If the cylinder is disassembled it must be lubricated as described in the cylinder instructions Actuator Identification The G Series Cylinder Act...

Страница 5: ...e factory set and do not require adjustment unless the actuator has been disassembled or actuator orientation has been changed Adjusting the Open Position Stop On 6A and 12A cylinder actuators the Open Position Stop is located in the end of the extension cap opposite the cylinder See Figure 2 The actuator must be mounted before adjusting the position stop 1 Loosen the Open Position jam nut 2 Adjus...

Страница 6: ...se personal injury or equipment damage Disconnect and lock out power to actuator before servicing 2 Disconnect and lock out the pneumatic power to prevent accidental operation of the actuator 3 Scribe corresponding lines on the valve and actuator to help align them during installation 4 Remove screws P4 and lockwashers P10 and lift actuator assembly off adaptor P1 See Figure 4 for connecting parts...

Страница 7: ...DeZURIK G Series Cylinder Actuator Used on BAW Butterfly Valves August 2012 Page 7 D10480 Figure 4 Connecting Parts Identification ...

Страница 8: ...rebuilding the cylinder Installing Cylinder 1 Scrape the old gasket material from the actuator housing and cylinder head then place a new gasket on the cylinder head 2 Install the cylinder rack rod assembly by sliding the rack rod through the rack B4 and fasten the cylinder to the housing B1 with screws B27 NOTE If the rack rod is not attached to the cylinder assembly clean the threads of both the...

Страница 9: ... spacer B21 from the end of the rack rod B6 5 Remove the screws B27 fastening the cylinder assembly to the actuator housing B1 and carefully remove the cylinder assembly and rack rod B6 by sliding it away from the actuator until the rack rod clears the actuator housing 6 Remove the screws B18 fastening the pointer to the gear B3 and remove pointer 7 Scribe corresponding lines on the cover B2 and h...

Страница 10: ... Fasten the actuator housing B1 to the adaptor plate P1 using screws P4 and lockwashers P10 4 Drive the pin B11 through the rack bearing B7 and housing B1 if worn rack bearing was removed 5 Apply a liberal amount of lubricant to the teeth and back of the rack B4 which contacts the rack bearing B7 and install the rack in the housing B1 6 Apply a liberal amount of lubricant to the teeth and journals...

Страница 11: ...en the cylinder to the housing B1 with screws B27 NOTE If the rack rod is not attached to the cylinder assembly clean the threads of both the rack rod and the cylinder shaft then apply Loctite to the cylinder shaft threads and screw the rack rod onto the cylinder shaft 9 Slide the spacer B21 onto the rack rod B6 and screw the jam nut B22 onto the rack rod B6 until the spacer is tight against the r...

Страница 12: ... power actuator can cause personal injury or equipment damage Disconnect and lock out power to actuator before servicing 2 Remove the actuator from the valve See Removing Actuator section 3 Rotate the actuator to the desired position 4 Install the actuator on the valve See Installing Actuator section Troubleshooting Condition Possible Cause Corrective Action Actuator closes to wrong position Close...

Страница 13: ...ll be the only effective guarantee or warranty binding on Seller despite anything to the contrary contained in the purchase order or represented by any agent or employee of Seller in writing or otherwise notwithstanding including but not limited to implied warranties THE FOREGOING REPAIR AND REPLACEMENT LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OBLIGATIONS AND LIABILITIES INCLUDING ALL W...

Отзывы: