SKTB.02.СК5.00.00.000 РЭ-01
DEZEGA
6
3. TECHNICAL DATA
The key specifications of the CARBO self-rescuer are listed in Table 1.
Table 1 – Key specifications of the self-rescuer
Parameter name
Parameter value
Rated duration
1
in accordance with EN 13794:2002
and AS/NZS 1716:2012 at lung ventilation, not less:
- 10 l/min
- 35 l/min
180 min
60 min
Breathing resistance (to inhalation or exhalation)
during operation, max:
0,75 kPa
Temperature of the inhaled gas, °C, not more
50
0
С
Volume of oxygen in the inhaled gas during the rated
duration, not less
21%
2
Maximum volume fraction of carbon dioxide in the
inhaled gas, not more
3%
Parameter name
Parameter value
Average volume fraction of carbon dioxide in the
inhaled gas during the rated duration, not more
1,5%
Volume of breathing bag, not less
6 L
Overall dimensions
(without waist and shoulder straps or bag):
- width
- height
- depth
215 mm
227 mm
106 mm
Weight
2,8±0,1 kg
Operating temperature
from -5 to +60
о
С
Relative humidity (at +35 °C) during operation and
storage
up to 100%
Information about service life, shelf life and warranty period is indicated in the Data Sheet which
is supplied with each SCSR.
1. Rated duration may vary under the escape conditions depending on physical activity and
physiological peculiarities of the user.
2. Short-time decrease of oxygen volume fraction in the inhaled gas down to 17% is allowed during
the first two minutes after the self-rescuer activation.
Содержание CARBO
Страница 2: ......
Страница 28: ...MS1 ENEU 112019 ...