![Dexter Laundry T-300 VENDED Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/dexter-laundry/t-300-vended/t-300-vended_operators-manual-installation-and-operation-instructions_2490398049.webp)
8514-302-001 REV B page 49
DRIVE GFI
VFD Ground
Fault
Condition
This error is a ground fault interruption on the VF
drive
Delay
Delay time is 12 seconds.
Action
Stop the machine and clear the cycle. Keep the door
locked until the machine has stopped moving and then
unlock the door.
Solution
Check VFD light code before turning off power. Check
the wiring connections to the drive and motor. Check
the ground wiring of the drive, motor and incoming
connection to ensure a proper ground is present.
Check for damaged motor wires.
DRIVE LV
VFD Low
Voltage
Condition
This error is low voltage on the VF drive
Delay
Delay time is 12 seconds.
Action
Stop the machine and clear the cycle. Keep the door
locked until the machine has stopped moving and then
unlock the door.
Solution
Check VFD light code before turning off power. Turn
the power off to the washer. Check the wiring
connections to the drive and motor. If no problem is
observed, turn on power to the washer and test. (See
Note) Measure the incoming line voltage.
DRIVE IF
VFD Internal
Fault
Condition
This error is an internal VF drive error
Delay
Delay time is 12 seconds.
Action
Stop the machine and clear the cycle. Keep the door
locked until the machine has stopped moving and then
unlock the door.
Solution
Check VFD fault light before turning off power. Turn
the power off to the washer. Wait one minute. Turn
the power on to the washer. If problem reappears,
contact your Dexter representative.
INVALID
DRIVE
Drive is not the
correct Dexter
version of the
Delta E-drive
Condition
The error indicates the VF drive is not a Dexter version
of the Delta E-drive.
Delay
Immediate (after the Dexter indication value is read
from drive). Drive indication value is read only at
power up, before starting a cycle, once every 24
hours, and in factory test mode.
Action
Stop the machine and clear the cycle. Keep the door
locked until the machine has stopped moving and then
unlock the door.
Solution
VFD has been replaced, disconnected, or removed.
Drive is not the correct Dexter version of the Delta E-
drive. Replace drive with Dexter Delta E-drive.
Содержание T-300 VENDED
Страница 4: ...8514 302 001 REV B page 4...
Страница 5: ...8514 302 001 REV B page 5...
Страница 6: ...8514 302 001 REV B page 6...
Страница 15: ...8514 302 001 REV B page 15 SIDE BY SIDE MOUNTING DIMENSIONS Figure 1 4 T 300 SIDE BY SIDE MOUNTING DETAIL...
Страница 17: ...8514 302 001 REV B page 17 SIDE BY SIDE MOUNTING DIMENSIONS Figure 1 4 T 350 SIDE BY SIDE MOUNTING DETAIL...
Страница 19: ...8514 302 001 REV B page 19 SIDE BY SIDE MOUNTING DIMENSIONS Figure 1 4 T 350 SWD SIDE BY SIDE MOUNTING DETAIL...
Страница 31: ...8514 302 001 REV B page 31 The figure below shows the sub menu options for Cycles...
Страница 34: ...8514 302 001 REV B page 34 The figure below shows the sub menu options for Plus Cycle Options...
Страница 37: ...8514 302 001 REV B page 37 The figure below shows the sub menu options for Settings...
Страница 39: ...8514 302 001 REV B page 39 The figure below shows the sub menu options for Usage...