press the “Enter” button to move to the minutes. Once the hours and
minute are both chosen, the “Enter” button must be held down for 3
seconds to confirm that RTC is meant to be reset to the complete entry.
7.
“Date”- Similar to “Time”, if a problem occurs and the RTC date is not accurate,
it can be reset to the current date using this option.
a.
The day of the month in “DATE” can be set by using the “Up” or “Down”
buttons to change the number that is flashing. Once the desired day of
the month is chosen, press the “Enter” button to move to the month of
the year. Once the desired month of the year is chosen, press the “Enter”
button to move to the year. Once the day, month and year are all chosen,
the “Enter” button must be held down for 3 seconds to confirm that RTC
is meant to be reset to the complete entry.
8.
“Out of Service” – The control can be put into an Out-of-Service mode via
manual programming. When the mode is “ON”, the control will scroll “OUT OF
SERVICE” on the display. The machine will not react to any vend input and will
not operate when in this mode. The factory default is “OFF”.
9.
“Drive Table”- The control knows what model of washer it is installed in based on
various inputs including information it receives from the Variable Frequency Drive
(VFD). However, because multiple VFD’s can be used on the same model,
depending on when it was manufactured, the “DRIVE TABLE” option is available.
“DRIVE ERROR 1” will display on the control when the Drive Table setting does
not match the appropriate VFD in the washer.
a.
Choose “Drive 3” for C4 models (ex. WC0600XA-12E
C4
X-)
b.
Choose “Drive 2” for C1, C2, or C3 models (ex. WC0600XA-12E
C2
X-)
c.
Choose “Drive 1” for WCAD models (ex.
WCAD
40KCS)
Contact your local Dexter distributor for more information.
10.
“Display Error Codes” – If the user programs the Display Error Codes to “OFF”,
the control will not display the non-critical errors (non-cycle ending errors) if they
occur during the cycle. This includes “Slow Fill Error” and “Slow Drain Error”
codes. The factory default is “ON”.
To reset all values in the Settings options to factory default, press “Enter” when the
“DEFAULT” prompt is shown. Press “Enter” again when the “RESET” prompt is shown to
confirm the action.
Содержание T-300 VENDED
Страница 4: ...8514 302 001 REV B page 4...
Страница 5: ...8514 302 001 REV B page 5...
Страница 6: ...8514 302 001 REV B page 6...
Страница 15: ...8514 302 001 REV B page 15 SIDE BY SIDE MOUNTING DIMENSIONS Figure 1 4 T 300 SIDE BY SIDE MOUNTING DETAIL...
Страница 17: ...8514 302 001 REV B page 17 SIDE BY SIDE MOUNTING DIMENSIONS Figure 1 4 T 350 SIDE BY SIDE MOUNTING DETAIL...
Страница 19: ...8514 302 001 REV B page 19 SIDE BY SIDE MOUNTING DIMENSIONS Figure 1 4 T 350 SWD SIDE BY SIDE MOUNTING DETAIL...
Страница 31: ...8514 302 001 REV B page 31 The figure below shows the sub menu options for Cycles...
Страница 34: ...8514 302 001 REV B page 34 The figure below shows the sub menu options for Plus Cycle Options...
Страница 37: ...8514 302 001 REV B page 37 The figure below shows the sub menu options for Settings...
Страница 39: ...8514 302 001 REV B page 39 The figure below shows the sub menu options for Usage...