![Dexter Laundry DDAD30HC-59 Series Dryers Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/dexter-laundry/ddad30hc-59-series-dryers/ddad30hc-59-series-dryers_operators-manual_2490297006.webp)
6
contact with an open flame such as the gas flame present in clothes dryers. The decomposition
products are highly corrosive and will cause damage to the dryer(s), ducts and clothes loads.
The operation of this appliance may affect the operation of other types of gas appliances,
which take their air for safe combustion from the same room. Adequate ventilation must be
provided to avoid back flow of gasses from other appliances in the same room. All other gas
appliances should be tested with the Dexter dryer in operation and all the windows and doors
closed
.
If in doubt, consult the appliance manufacturer(s).
4.
ELECTRICAL REQUIREMENTS
. The electrical power requirements necessary to
operate the unit satisfactorily are listed on the serial plate located on the back panel of each
dryer. The electrical connection should be made to the terminal board in the control box, on the
rear of the unit, using copper conductors of 20A minimum capacity. It is absolutely necessary
that the dryer be grounded to a known ground.
The installation must meet the National Electrical Requirements of the country of
installation. Individual 20A circuit breakers for each dryer are required. The installer must
provide a disconnect switch, which will interrupt both lines. It may be a local or national
requirement to provide an electrical interruption switch visible and accessible from the room in
which the dryer is installed. The wiring diagram is located in the control box on the back of the
dryer.
5.
GAS REQUIREMENTS
. The complete gas requirements necessary to operate the dryer
satisfactorily are listed on the serial plate located on the back panel of the dryer.
This appliance is adjusted for a G20 gas supply; please refer to the table below for country and
regulator setting.
NATURAL GAS
HEAT INPUT
90000 BTU/HR (26.38kW) GROSS
72000 BTU/HR (21.12kW) NET PER DRUM MAX
GAS FLOW RATE
2.2 m
3
PER HOUR PER DRUM
BURNER PRESSURE
3.5 in. H
2
O (8.7 mbar)(0.87 kPa)
INJECTOR SIZE
NO. 32 DRILL (2.95 mm)
ADJUSTMENT REQUIRED PER COUNTRY
The inlet gas connection to the unit is ISO 7-RC 3/4 thread. The connection to the appliance
COUNTRY CATEGORY
SUPPLY
PRESSURE
Normal / Minimum mbar
REGULATOR SETTING
mbar (kPa)
GB, IE, ES, PT, FI,
AT, IT, DK, SE, GR
I2H
20 / 17
8.7 (0.87)
FR
I2Er
20 / 17
8.7 (0.87) (G20) / 12.0 (1.20) (G25)
DE
I2E
20 / 17
8.7 (0.87)
NL
I2L
25 / 20
12.0 (1.20)
Содержание DDAD30HC-59 Series Dryers
Страница 3: ...3 Figure 1 30 Stack Dryer Dimensions inches mm ...
Страница 11: ...11 ...